82-18-51: Airesearch Engine Starters Installed
FAA order 82-18-51 is an airworthiness directive in force since November 23, 1982. The FAA's subject line: Airesearch Engine Starters Installed. It names Douglas DC-8: about 6 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: engine.
What it applies to as the FAA lists it
- Kind of product
- Aircraft
- Makes
- The Boeing Company
- Models
- DC-8-71, DC-8-72, DC-8-73
- On this site
- Douglas DC-8 6 registered
Dates and paperwork
- In force since
- November 23, 1982
- Docket
- Unknown
- Status
- Current
- The FAA's document
- Read the order on the FAA's site
The order itself the regulatory text, as published
Show the full text (2,325 characters)
82-18-51 MCDONNELL DOUGLAS: Amendment 39-4499. Applies to McDonnell Douglas Model DC-8-70 series airplanes with P/N 3505154-18-1 series Airesearch engine starters installed, certificated in all categories. Compliance required within 20 flight hours after receipt of this AD, and at intervals not to exceed 20 flight hours thereafter. \n\n\tTo detect starter output shaft bearing distress, accomplish the following, unless already accomplished: \n\n\tA)\tRemove the magnetic portion (knurled knob, bayonet type, quick disconnect) of each starter drain plug and check for the presence of metallic particles. The following action shall be taken when the degree of contamination has been determined: \n\n\t\t1)\tA plug that is clean or having light fuzz is normal and acceptable. Clean plug as necessary, reinstall, and continue starter operation. \n\n\t\t2)\tIf light metal particle accumulation is observed on the magnetic portion of the plug, drain the starter oil and observe color and odor of the oil. \n\n\t\t\ta)\tIf the oil is transparent, reservice the starter with clean oil, clean the drain plug, reinstall, and continue starter operation. If metal is again observed at any subsequent inspection, replace the starter with a serviceable unit. \n\n\t\t\tb)\tIf the oil is black, or has a burnt smell, replace the starter with a serviceable unit. \n\n\t\t3)\tIf metal accumulation in excess of that defined in 2), above, is observed on the magnetic portion of the drain plug, replace the starter with a serviceable unit. \n\n\tB)\tWhen a P/N 3505154-19-1 series or subsequent approved P/N starter is installed, inspection per this AD is terminated. \n\n\tC)\tSpecial flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate airplanes to a base for the accomplishment of inspections and repairs required for the purposes of this AD when approved by the Manager, Los Angeles Aircraft Certification Office, FAA, Northwest Mountain Region. \n\n\tD)\tAlternate means of compliance which providean equivalent level of safety may be used when approved by the Manager, Los Angeles Aircraft Certification Office, FAA, Northwest Mountain Region. \n\n\tThis amendment becomes effective November 23, 1982, and was effective earlier to those recipients of Telegraphic AD T82-18-51 dated August 31, 1982.
Related safety bulletins advice on the same designs, not orders
2019-02-19NE-19-03 · Escape Slide Maintenance Tasks and Intervals - JASC 2565
2014-11-24NM-15-03 · Flight Controls
2008-12-11NM-09-03 · Engine Fuel and Control - Implementing Fuel Tank System Airworthiness Limitations
2006-07-27NM-06-57 · Reports of damage to airplanes and to property on the ground caused by blue or clear ice falling from airplanes.
Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 6, 2026. Connections as data: /graph/directive/82-18-51.json · aircraft systems.