51-25-02: Circuit Breaker Cover

FAA order 51-25-02 is an airworthiness directive. The FAA's subject line: Circuit Breaker Cover. System: electrical power.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Martin-Marietta Corporation
Models
202, 202A

Dates and paperwork

Docket
Unknown
Status
Current
The FAA's document
Read the order on the FAA's site

The order itself the regulatory text, as published

Show the full text (493 characters)
51-25-02 MARTIN: Applies to All Models 202 and 202A Airplanes. Compliance required by January 1, 1952. Install cover over D7231-125 inverter remote reset circuit breaker terminals to prevent inadvertent shorting between "MAIN" and "CONTROL" terminals. Compliance may be made in same manner or equivalent to Martin Service Instruction Letter No. 8 dated September 10, 1951. This supersedes the first item in AD 51-11-01 requiring the redesign of the d.c. input circuit breaker mounting.