47-16-01: Circuit Breaker Switches in Each Nacelle Junction Box

FAA order 47-16-01 is an airworthiness directive. The FAA's subject line: Circuit Breaker Switches in Each Nacelle Junction Box. It names Douglas C-54: about 7 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: electrical power.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
The Boeing Company
Models
C54-DC, C54A-DC, C54B-DC, C54D-DC, C54E-DC, C54G-DC, DC-4
On this site
Douglas C-54 7 registered

Dates and paperwork

Docket
Unknown
Status
Current
The FAA's document
Read the order on the FAA's site

The order itself the regulatory text, as published

Show the full text (1,530 characters)
47-16-01 DOUGLAS: (Was Mandatory Note 16 AD-762-7.) Applies to C-54 and DC-4 Aircraft. \n\n\tTo be complied with not later than September 1, 1947. \n\n\tA.\tIn those aircraft having the ammeter shunts in the positive generator leads, install two circuit breakers or circuit breaker switches in each nacelle junction box and reconnect each ammeter lead through one of these circuit breakers. Any type or variety of 10-ampere circuit break may be used, with the exception of the automatic-reset type. \n\n\tB.\tInstall a circuit breaker or circuit breaker switch in the main junction box and connect in series with the voltmeter circuit wire PJ-34 at the (d.c.) buss. Any type or variety of 10-ampere circuit breaker may be used, with the exception of the automatic-reset type. The nonoverride variety of circuit breaker is preferable. \n\n\tC.\tInstall for Heinemann type AM 1614-15-28-2 or equivalent, 15-ampere circuit breaker switches or circuit breakers, at the regulator location, in the leads to the B terminal of the voltage regulators; wires PA-530, PA-531, PA-730, and PA-731. The usual thermal circuit breaker or fuse does not provide sufficient protection to meet the peculiar requirements of a protective device for a generator field circuit application. \n\n\tAdditional information on the foregoing changes are described by Douglas Drawing No. 4350951 entitled "Rework of Generator Field Lead and Volt-Ammeter Lead Circuit Protection". A Douglas Aircraft Service Bulletin on this subject is also being issued.

Related safety bulletins advice on the same designs, not orders

2014-11-24NM-15-03 · Flight Controls

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 6, 2026. Connections as data: /graph/directive/47-16-01.json · aircraft systems.