The U.S. aircraft register, updated daily
FAA orders · airworthiness directive · current

47-10-11: Fire Detector Replacement

FAA order 47-10-11 is an airworthiness directive. The FAA's subject line: Fire Detector Replacement. System: other and general.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Lockheed Aircraft Corporation
Models
49-46

Dates and paperwork

Docket
Unknown
Status
Current
The FAA's document
Read the order on the FAA's site

The order itself the regulatory text, as published

Show the full text (509 characters)
47-10-11 LOCKHEED: (Was Mandatory Note 13 of AD-763-3.) Applies to All Model 49 Serials Up to and Including 2088. Compliance required not later than 200 hours of operation after March 1, 1947. Replace all Fenwall Type S-2223 fire detector units on fire seals and firewalls and in nacelles and cabin heater compartments with Type 17343-3-450 fire detector units (100 units for each Model 49-51 aircraft, 116 units for each Model 49-46 aircraft.) (LAC Service Bulletin 49/SB-65 covers this same subject.)

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 6, 2026. Connections as data: /graph/directive/47-10-11.json · aircraft systems.