47-10-02: Elevator Tab Control Circuit Breaker
FAA order 47-10-02 is an airworthiness directive. The FAA's subject line: Elevator Tab Control Circuit Breaker. System: flight controls.
What it applies to as the FAA lists it
- Kind of product
- Aircraft
- Makes
- Lockheed Aircraft Corporation
- Models
- 49-46
Dates and paperwork
- Docket
- Unknown
- Status
- Current
- The FAA's document
- Read the order on the FAA's site
The order itself the regulatory text, as published
Show the full text (536 characters)
47-10-02 LOCKHEED: (Was Mandatory Note 1 of AD-763-3). Applies Only to Model 49 Serial Numbers 2021 to 2054, Inclusive.
Compliance required prior to March 1, 1947.
Install an AN 3161-P15 (or equivalent) non-trip-free circuit breaker in the elevator tab control circuit. The breaker is to be located in the pilots' control stand, with access through a plate immediately forward of the control quadrant. Minor wiring changes to connect the circuit breaker are also necessary. (LAC Service Bulletin 049/SB-4 covers this same subject.)
Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 6, 2026. Connections as data: /graph/directive/47-10-02.json · aircraft systems.