The U.S. aircraft register, updated daily
FAA orders · airworthiness directive · current

2017-20-09: Turbine Engine Bypass Section

FAA order 2017-20-09 is an airworthiness directive in force since November 13, 2017. The FAA's subject line: Turbine Engine Bypass Section. It names the General Electric CF34-8E5, General Electric CF34-8E5A2, General Electric CF34 series engines: about 1,373 aircraft on the U.S. register today across them, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Engine
Makes
General Electric Company
Models
CF34-8E2, CF34-8E2A1, CF34-8E5, CF34-8E5A1, CF34-8E5A2, CF34-8E6, CF34-8E6A1
Engine series
General Electric CF34-8E5 698 aircraft
General Electric CF34-8E5A2 3 aircraft
General Electric CF34 series 672 aircraft

Dates and paperwork

In force since
November 13, 2017
Published
October 6, 2017 (signed September 28, 2017)
Docket
FAA-2017-0254
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

We are adopting a new airworthiness directive (AD) for all General Electric Company (GE) CF34-8E model turbofan engines. This AD was prompted by a report that using a certain repair procedure for the fan outlet guide vane (OGV) frame could alter the strength capability of the fan OGV frame. This AD requires replacement of all fan OGV frames [[Page 46670]] repaired using this procedure. We are issuing this AD to address the unsafe condition on these products.

The order itself the regulatory text, as published

Show the full text (3,746 characters)
Adoption of the Amendment Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: PART 39--AIRWORTHINESS DIRECTIVES 0 1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. Sec. 39.13 [Amended] 0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): 2017-20-09 General Electric Company: Amendment 39-19066; Docket No. FAA-2017-0254; Product Identifier 2017-NE-10-AD. (a) Effective Date This AD is effective November 13, 2017. (b) Affected ADs None. (c) Applicability This AD applies to all General Electric Company (GE) CF34-8E2; CF34-8E2A1; CF34-8E5; CF34-8E5A1; CF34-8E5A2; CF34-8E6; and CF34- 8E6A1 model turbofan engines. (d) Subject Joint Aircraft System Component (JASC), 7270, Turbine Engine Bypass Section. (e) Unsafe Condition This AD was promptedby a report that using a certain repair procedure for the fan outlet guide vane (OGV) frame could alter the strength capability of the fan OGV frame. We are issuing this AD to prevent failure of the fan OGV frame, engine separation, and loss of the airplane. (f) Compliance Comply with this AD within the compliance times specified, unless already done. (g) Required Actions (1) For engines with a fan OGV frame installed that was repaired using GE CF34-8E Engine Manual, GEK 112031, 72-00-23, REPAIR 006: (i) If the fan OGV frame has 24,900 cycles since new (CSN) or more on the effective date of this AD, remove the OGV frame from service within 100 cycles after the effective date of this AD. (ii) If the OGV frame has less than 24,900 CSN on the effective date of this AD, remove the fan OGV frame from service at the next shop visit after the effective date of this AD, or before exceeding 25,000 CSN, whichever occurs earlier. (2) After the effective date of this AD, do not install a fan OGV frame that was repaired using GE CF34-8E Engine Manual, GEK 112031, 72-00-23, REPAIR 006. (h) Definition For the purpose of this AD, an ``engine shop visit'' is the induction of an engine into the shop for maintenance involving the separation of pairs of major mating engine flanges. (i) Alternative Methods of Compliance (AMOCs) (1) The Manager, ECO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to the attention of the person identified in paragraph (j)(1) of this AD. You may email your request to: [email protected]. (2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the managerof the local flight standards district office/certificate holding district office. (j) Related Information (1) For more information about this AD, contact David Bethka, Aerospace Engineer, ECO Branch, FAA, 1200 District Avenue, Burlington, MA 01803; phone: 781-238-7129; fax: 781-238-7199; email: [email protected]. (2) For General Electric service information identified in this AD, contact General Electric Company, GE-Aviation, Room 285, 1 Neumann Way, Cincinnati, OH 45215, phone: 513-552-3272; fax: 513- 552-3329; email: [email protected]. You may view this service information at the FAA, Engine and Propeller Standards Branch, 1200 District Avenue, Burlington, MA. For information on the availability of this material at the FAA, call 781-238-7125. (k) Material Incorporated by Reference None.

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 6, 2026. Connections as data: /graph/directive/2017-20-09.json · aircraft systems.