2015-23-07: Electrical Power

FAA order 2015-23-07 is an airworthiness directive in force since December 22, 2015. The FAA's subject line: Electrical Power. It names Bombardier BD-100 Challenger 300 and 350: about 883 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: cabin, seats and restraints.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Bombardier Inc.
Models
BD-100-1A10 (Challenger 300)
On this site
Bombardier BD-100 Challenger 300 and 350 883 registered

Dates and paperwork

In force since
December 22, 2015
Published
November 17, 2015 (signed October 30, 2015)
Docket
FAA-2015-0929
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc. Model BD-100-1A10 (Challenger 300) airplanes. This AD was prompted by multiple reports of chafing found on an electrical wiring harness in the aft equipment bay, caused by contact between the wiring harness and a neighboring hydraulic line. This AD requires an inspection, repair if necessary, and modification of the wiring harness installation to ensure that the wiring harness routing is correct and a minimum clearance between the wire and the hydraulic line is maintained. We are issuing this AD to detect and correct chafing on an electrical wiring harness, which could cause an electrical short circuit or lead to a malfunction of the flight control system, the engine indication system, or the hydraulic power control system; and adversely affect the continued safe operation and landing of the airplane.

The order itself the regulatory text, as published

Show the full text (6,168 characters)
Adoption of the Amendment Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: PART 39--AIRWORTHINESS DIRECTIVES 0 1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. Sec. 39.13 [Amended] 0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): 2015-23-07 Bombardier, Inc.: Amendment 39-18323. Docket No. FAA- 2015-0929; Directorate Identifier 2014-NM-218-AD. (a) Effective Date This AD becomes effective December 22, 2015. (b) Affected ADs None. (c) Applicability This AD applies to Bombardier, Inc. Model BD-100-1A10 (Challenger 300) airplanes, certificated in any category, having serial numbers 20003 through 20382 inclusive, 20384, and 20386. (d) Subject Air Transport Association (ATA) of America Code 24, Electrical Power. (e) Reason This AD wasprompted by multiple reports of chafing found on an electrical wiring harness in the aft equipment bay, caused by contact between the wiring harness and a neighboring hydraulic line. We are issuing this AD to detect and correct chafing on an electrical wiring harness, which could cause an electrical short circuit or lead to a malfunction of the flight control system, the engine indication system, or the hydraulic power control system; which could adversely affect the continued safe operation and landing of the airplane. (f) Compliance Comply with this AD within the compliance times specified, unless already done. (g) Inspection, Repair, and Preventive Modification Within 36 months after the effective date of this AD, do the actions required by paragraphs (g)(1) and (g)(2) of this AD. (1) Do a one-time general visual inspection to detect damage (including wear and chafing) of the wiring harness, in accordance with the Accomplishment Instructions of Bombardier,Inc. Service Bulletin 100-24-24, dated June 6, 2014. Repair any damage before further flight, in accordance with the Accomplishment Instructions of Bombardier, Inc. Service Bulletin 100-24-24, dated June 6, 2014; except, where Bombardier, Inc. Service Bulletin 100-24-24, dated June 6, 2014, specifies to contact Bombardier for repair instructions, repair using a method approved by the Manager, New York Aircraft Certification Office (ACO), ANE-170, FAA; or Transport Canada Civil Aviation (TCCA); or Bombardier, Inc.'s TCCA Design Approval Organization (DAO). (2) Modify the wiring harness routing, in accordance with the Accomplishment Instructions of Bombardier, Inc. Service Bulletin 100-24-24, dated June 6, 2014. (h) Definition of General Visual Inspection For the purposes of this AD, a general visual inspection is a visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to ensure visual access to all surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked. (i) Other FAA AD Provisions The following provisions also apply to this AD: (1) Alternative Methods of Compliance (AMOCs): The Manager, New York ACO, ANE-170, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the ACO, send it to ATTN: Program Manager, Continuing Operational Safety, FAA, New York ACO, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone: 516-228- 7300; fax: 516-794-5531. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/ certificate holding district office. The AMOC approval letter must specifically reference this AD. (2) Contacting the Manufacturer: For any requirement in this AD to obtain corrective actions from a manufacturer, the action must be accomplished using a method approved by the Manager, New York ACO, ANE-170, FAA; or TCCA; or Bombardier, Inc.'s TCCA DAO. If approved by the DAO, the approval must include the DAO-authorized signature. (j) Related Information Refer to Mandatory Continuing Airworthiness Information (MCAI) Canadian Airworthiness Directive CF-2014-32, dated September 8, 2014, for related information. This MCAI may be found in the AD docket on the Internet at http://www.regulations.gov/#!documentDetail;D=FAA-2015-0929-0002. [[Page 71686]] (k) Material Incorporated by Reference (1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. (2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise. (i) Bombardier, Inc. Service Bulletin 100-24-24, dated June 6, 2014. (ii) Reserved. (3) For service information identified in this AD, contact Bombardier, Inc., 400 C[ocirc]te-Vertu Road West, Dorval, Qu[eacute]bec H4S 1Y9, Canada; telephone: 514-855-5000; fax: 514- 855-7401; email: [email protected]; Internet http://www.bombardier.com. (4) You may view this service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. (5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

Related safety bulletins advice on the same designs, not orders

2022-05-17AIR-22-02R1 · PITOT/STATIC ANTI-ICE SYSTEM
2022-02-25AIR-22-02 · PITOT/STATIC ANTI-ICE SYSTEM
2021-03-22NM-18-32R1 · Electrical Power - Direct Current Power Center
2018-12-03NM-18-32 · Electrical Power - Direct Current Power Center

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 6, 2026. Connections as data: /graph/directive/2015-23-07.json · aircraft systems.