The U.S. aircraft register, updated daily
Parts · Electrical power

Contactor

153 failure reports named the contactor in the last ten years, 546 since 1995, most often on the Airbus A320; the condition most often found was "failed". 94 FAA approvals let 9 companies make a replacement contactor, Hartman Electrical Mfg holding the most (55).

Reports by year

015304560199520002005201020152020202582026
Reports by year, as a table
reports
199511
199610
19979
19989
19999
200027
200136
200260
200341
200417
200514
20066
200712
200816
200910
201011
201115
201228
201326
201412
201514
201616
201717
201816
201921
202013
202110
20227
202315
202415
202515
20268

How it failed the condition found, last ten years

failed27burned23faulted16defective14faulty14damaged10inoperative9dirty5loose4tripped4
Conditions found, as a table
reports
failed27
burned23
faulted16
defective14
faulty14
damaged10
inoperative9
dirty5
loose4
tripped4

Engines most often reporting it

Approved replacement parts 94 parts manufacturer approvals

A parts manufacturer approval (PMA) lets a company other than the aircraft's maker make a contactor and sell it as an approved part for the models named. These are the companies holding such approvals for a contactor:

For these models most: Mcdonnell Douglas MD-11 (20), Boeing 777 (18), Mcdonnell Douglas DC-10 (13), Mcdonnell Douglas DC-9 (10), Mcdonnell Douglas Aircraft Co MD-88 (10), Boeing 767 (7), Boeing 747 (7), Bombardier CL-600 Challenger and CRJ (6), Boeing 757 (6), Gulfstream G-IV Gulfstream IV (4), Piper PA-32 Cherokee Six, Lance and Saratoga (3), Piper PA-28 Cherokee, Warrior, Archer and Arrow (3).

MakerPartReplacesFitsGrantedStatus
Astronics - Advanced Electronic SystemsCONTACTOR, BATTERY BUS 1181-21181-2Eclipse Aerospace EA5002022-03-28current
Astronics - Advanced Electronic SystemsCONTACTOR, BATTERY BUS (BBC) 1181-31181-3Eclipse Aerospace EA5002022-03-28current
Te Connectivity Corporation D/B/A Hartman Electrical MfgContactor BP-394ABP-394AThe Sikorsky S-92A2021-06-03current
Te Connectivity Corporation D/B/A Hartman Electrical MfgContactor A-1077BBA-1077BBThe Sikorsky S-92A2021-06-03current
Hartman Electrical MfgCONTACTOR DP25CDP25CThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2018-01-31current
Hartman Electrical MfgCONTACTOR DP31EDP31EThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2018-01-31current
Hartman Electrical MfgCONTACTOR KAD100B7CKAD100B7CThe Boeing Company 777-200F SERIES, 777-3000ER SERIES2018-01-31current
Hartman Electrical MfgCONTACTOR BP494G-1BP494G-1The Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP353DBP353DThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR KALF512B2117CKALF512B2117CThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP353FBP353FThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR KAF366B9CKAF366B9CThe Boeing Company 777-200 SERIES, 777-200ER SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP494JBP494JThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR KAF66B8CKAF66B8CThe Boeing Company 777-200 SERIES, 777-200ER SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR DP31DDP31DThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR KAD100B3CKAD100B3CThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP493-3BP493-3The Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP494GBP494GThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP353D-1BP353D-1The Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR BP353EBP353EThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR KAF175B1CKAF175B1CThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Hartman Electrical MfgCONTACTOR KAF501B10CKAF501B10CThe Boeing Company 777-200 SERIES, 777-200LR SERIES,...2017-06-01current
Duncan Aviation INCContactor/Circuit Breaker Mount Assy DWG-0000003144-3.1.0Modification PartCessna Aircraft Company 525C2016-11-09current
Leach International, North AmericaContactor AHJS-CXA-040AHJS-CXA-040McDonnell Douglas DC-10-10F, DC-10-15, DC-10-302008-08-03current
Hartman Electrical MfgContactor D18ZZCBombardier P/N: D18ZZABombardier, Inc. CL-600-2B19 Regional Jet Series 2002006-11-08current
Hartman Electrical MfgContactor D7GSZBombardier P/N: D7GRZBombardier, Inc. CL-600-2B19 Regional Jet Series 2002006-11-08current
Aero Accessories INCContactor AAF7-64-1Airborne elapsed time indicator, F7-64-1Cessna U206F, G, TU206F2003-07-27current
Leach International, North AmericaContactor HD-A3F-0115D0163-1McDonnell Douglas DC-10-10, DC-10-10F, DC-10-152003-06-01current
Aero Accessories INCContactor AAF7-64-2Airborne F7-64-2Piper PA-32-( ), PA-32S-( ), PA-32R-( )2003-01-06current
Aero Accessories INCContactor AA4A2-201Airborne contactor, F7-64-1Cessna U206F, G, TU206F2002-10-13current
Leach International, North AmericaContactor H-A10N-109H-A10N-109Boeing 767-400ER Series2000-10-03current
Hartman Electrical MfgContactor B-461D-15D0271-2McDonnell Douglas MD-11, MD-11F2000-04-23current
Leach International, North AmericaContactor H-C7NGulfstream H-C7NGulfstream G-IV1998-11-17current
Leach International, North AmericaContactor A-A4NGulfstream A-A4NGulfstream G-IV1998-11-17current
Leach International, North AmericaContactor Z-A6NGulfstream Z-A6NGulfstream G-IV1998-11-17current
Leach International, North AmericaContactor ZC-B3NGulfstream ZC-B3NGulfstream G-IV1998-11-17current
Leach International, North AmericaContactor AH-C9N-033Boeing/Douglas Products Division P/N AH-C9N-033McDonnell Douglas Model(s) DC-10-10, -30F, DC-9-311998-04-05current
Leach International, North AmericaContactor H-A9A-048Bombardier, Inc. H-A9A-048Bombardier, Inc. CL600-2B19 (Regional Jet Series 100)1997-01-08current
Leach International, North AmericaContactor P600-A803-E015Bombardier, Inc. P600-A803-E015Bombardier, Inc. CL600-2B19 (Regional Jet Series 100)1997-01-08current
Leach International, North AmericaContactor HD-A9A-021McDonnell Douglas HD-A9A-021McDonnell Douglas DC-10-10, -10CF, -151996-07-14current
Leach International, North AmericaContactor AH-C6A-020McDonnell Douglas AH-C6A-020McDonnell Douglas MD-111996-07-14current
Leach International, North AmericaContactor HCTD-A1N-030McDonnell Douglas HCTD-A1N-030McDonnell Douglas MD-11, MD-11F, MD-11C1996-07-14current
Leach International, North AmericaContactor HD-A3F-011McDonnell Douglas HD-A3F-011McDonnell Douglas DC-9-11, -12, -131996-07-14current
Leach International, North AmericaContactor HTD-C7N-012McDonnell Douglas HTD-C7N-012McDonnell Douglas MD-11, MD-11F, MD-11C1996-07-14current
Leach International, North AmericaContactor ZC-A9X-036McDonnell Douglas ZC-A9X-036McDonnell Douglas MD-11, MD-11F, MD-11C1996-07-14current
Leach International, North AmericaContactor WC-A9N-019McDonnell Douglas WC-A9N-019McDonnell Douglas MD-11, MD-11F, MD-11C1996-07-14current
Leach International, North AmericaContactor ZC-B9N-034McDonnell Douglas ZC-B9N-034McDonnell Douglas MD-11, MD-11F, MD-11C1996-07-14current
Leach International, North AmericaContactor Z-B7N-059McDonnell Douglas Z-B7N-059McDonnell Douglas MD-11, MD-11F, MD-11C1996-07-14current
Leach International, North AmericaContactor ZCD-A2X-021McDonnell Douglas ZCD-A2X-021McDonnell Douglas DC-10-10, -10CF, -151996-07-14current
Leach International, North AmericaContactor ZA9A038Canadair P/N ZA9A038Canadair Model(s) CL600-2B19 (Regional Jet...1995-08-30current
Leach International, North AmericaContactor HD-A3F-011McDonnell Douglas P/N HD-A3F-011McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Leach International, North AmericaContactor ZCD-A2X-021McDonnell Douglas P/N ZCD-A2X-021McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Leach International, North AmericaContactor ZC-A9X-036McDonnell Douglas P/N ZC-A9X-036McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Leach International, North AmericaContactor HTD-C7N-012McDonnell Douglas P/N HTD-C7N-012McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Leach International, North AmericaContactor Z-B7N-059McDonnell Douglas P/N Z-B7N-059McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Leach International, North AmericaContactor HCTD-A1N-030McDonnell Douglas P/N HCTD-A1N-030McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Leach International, North AmericaContactor ZC-B9N-034McDonnell Douglas P/N ZC-B9N-034McDonnell Douglas Model(s) MD-11, MD-11F1995-08-30current
Hamilton Sundstrand CorporationContactor #942D055-2 Dwg. No. Dwg....Boeing P/N 60B40021-2Boeing 7471995-03-26current
Hartman Electrical MfgContactor - DC SPDT, 60 Amps NN-233CBombardier NN-233CBombardier, Inc. CL-600-2B191994-11-27current
Hartman Electrical MfgContactor - DC SPDT, 100 Amps NN-449BBombardier NN-449BBombardier, Inc. CL-600-2B191994-11-27current
Hartman Electrical MfgContactor - 3 PDT Sidestable B-209EMcDonnell Douglas B-209EMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - 3PDT Sidestable 50 AMP, 115/200 VAC, 400 Hz D-7GRMcDonnell Douglas D-7GRMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - 3PST NO Sidestable 50 AMP, 115/200 VAC, 400Hz DR-7VCMcDonnell Douglas DR-7VCMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - AC Power 250 AMP, 3 PST NO BR-125BCMcDonnell Douglas BR-125BCMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - SPDT Center Off 100 AMP, 28 VDC D-31BAAMcDonnell Douglas D-31BAAMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - 3PDT Center Off 50 AMP, 115/200 VAC 400Hz D-18McDonnell Douglas D-18McDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - 3PDT Side Stable 100 AMP 115/200 Volts 400 Hz D-25BAAMcDonnell Douglas D-25BAAMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Hartman Electrical MfgContactor - 3 PST NO 350 AMP 120/208V 400Hz B-429CAMcDonnell Douglas B-429CAMcDonnell Douglas MD-11, -11F1994-01-20current
Hartman Electrical MfgContactor - 3PDT Center Off 100 AMP, 115 Volts, 400 Hz D-31TFAMcDonnell Douglas D-31TFAMcDonnell Douglas DC-10-10, -10F, -151994-01-20current
Sundstrand Electric Power SysContactor 942D055-2Boeing 60B40021-2Boeing 7471993-12-16current
Hartman Electrical MfgContactor - 3PDT Center off Hermietically Sealed DHR-18-1Hartman Elect. DHR-18-1Fokker F.28 Mark 4000, 01001993-10-20current
Hartman Electrical MfgContactor - 2 PST NO 400 28 VDC A-1148BHartman Elect. A-1148BAerospatiale ATR42, ATR721993-10-20current
Hartman Electrical MfgContactor - 3PDT Center off 60 Amp 115/200V 400 Hz B-227Hartman Elect. B-227Fokker F.28 Mark 40001993-10-20current
Hartman Electrical MfgContactor B-451Hartman Elect. B-451Boeing 737-200, -300, -4001993-10-20current
Hartman Electrical MfgContactor D-7ACHartman Elect. D-7ACBoeing 7571993-10-20current
Hartman Electrical MfgContactor A-1077DDHartman Elect. A-1077DDBoeing 757, 7671993-10-20current
Hartman Electrical MfgContactor B-430-1Boeing S281T004-1Boeing 757, 7671993-10-20current
Hartman Electrical MfgContactor - 2 PST Hermetically Sld DH-7MLHartman Elect. DH-7MLMcDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor - SPDT Center Off 100 Amp 28 VDC D-31BAAHartman Elect. D-31BAAMcDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor - 2 PST Hermetically Sld DH-7MNHartman Elect. DH-7MNMcDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor B-429-1Boeing S281T004-2Boeing 757, 7671993-10-20current
Hartman Electrical MfgContactor - SPDT Centeroff DHR-31BAHartman Elect. DHR-31BAMcDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor - DPDT DH-7PFMcDonnell Douglas 7596593McDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor D-31CBoeing 10-614445-24Boeing 737-200, -300, -4001993-10-20current
Hartman Electrical MfgContactor D-25BDHartman Elect. 10-61445-23Boeing 757, 7671993-10-20current
Hartman Electrical MfgContactor D-18FHartman Elect. D-18FBoeing 747-400, 7671993-10-20current
Hartman Electrical MfgContactor - SPDT Center Off Sealed DR-18E-5Hartman Elect. DR-18E-5Boeing 707, 720, 7271993-10-20current
Hartman Electrical MfgContactor B-430ZBoeing 60B00010-25Boeing 747-100, -200, -3001993-10-20current
Hartman Electrical MfgContactor B-429WBoeing 60B40021-3Boeing 747-100, -200, -3001993-10-20current
Hartman Electrical MfgContactor - 3 PDT Centeroff 50 Amp 115/200 VAC 400 Hz D-18Hartman Elect. D-18McDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor - 3 PDT Hermetically Sld DHR-7BEHartman Elect. DHR-7BEMcDonnell Douglas DC-9-11, -12, -131993-10-20current
Hartman Electrical MfgContactor - 3 PST NO Sidestable 50 Amp 115/200 VAC 400Hz DR-7VCMcDonnell Douglas 5D0162-1McDonnell Douglas DC-9-11, -12, -131993-10-20current
Westinghouse Electric CORP, Electrical Systems DivContactor 942D055-2Boeing 60B40021-2Boeing 7471992-03-10current
Hartman Electrical MfgContactor - 3 PST NO Side Stable, 50 Amp, 115/200 VAC, 400Hz DR-7VCHartman Electric DR-7VCMcDonnell Douglas MD-11, -11F1991-09-03current

Sources: the FAA's service difficulty reports since 1995 (a report is a part that failed and was fixed, as filed by an airline, repair station or owner; the count shows reporting as much as reliability) and the parts manufacturer approvals in the FAA's Dynamic Regulatory System. The part name is the reporters' and the approval holders' own words, reduced to the first plain words so that spellings meet.