Hartman Electrical Mfg
Holds 164 approvals to make replacement parts. FAA spelling: Hartman Electrical Mfg.
Replacement parts approved 164 parts manufacturer approvals, 164 current · Mansfield, OH
A parts manufacturer approval lets a company make a replacement part for someone else's aircraft or engine and sell it as an approved part. This company's approvals are mostly for other and general (120), electrical power (44).
Boeing 777 21Mcdonnell Douglas MD-11 15Mcdonnell Douglas Aircraft Co MD-88 14Mcdonnell Douglas DC-9 14Boeing 747 13Mcdonnell Douglas DC-10 13Boeing 767 10Boeing 757 9Boeing 737 8British Aerospace BAE 146 7Aerospatiale/Aeritalia ATR 42 6Aerospatiale ATR 72 6
2018-01-31CIRCUIT BREAKER CBP-R150 · replaces CBP-R150 · 777F SERIES.
2018-01-31CONTACTOR DP25C · replaces DP25C · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2018-01-31CONTACTOR DP31E · replaces DP31E · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2018-01-31CONTACTOR KAD100B7C · replaces KAD100B7C · 777-200F SERIES, 777-3000ER SERIES
2017-06-01CONTACTOR BP494G-1 · replaces BP494G-1 · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR BP353D · replaces BP353D · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR KALF512B2117C · replaces KALF512B2117C · 777-200 SERIES, 777-200LR SERIES, 777-3000 SERIES
2017-06-01CONTACTOR BP353F · replaces BP353F · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR KAF366B9C · replaces KAF366B9C · 777-200 SERIES, 777-200ER SERIES, 777-200LR SERIES
2017-06-01CONTACTRO BP353F-1 · replaces BP353F-1 · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR BP494J · replaces BP494J · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR KAF66B8C · replaces KAF66B8C · 777-200 SERIES, 777-200ER SERIES, 777-200LR SERIES
2017-06-01CONTACTOR DP31D · replaces DP31D · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR KAD100B3C · replaces KAD100B3C · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR BP493-3 · replaces BP493-3 · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR BP494G · replaces BP494G · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR BP353D-1 · replaces BP353D-1 · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR BP353E · replaces BP353E · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CIRCUIT BREAKER CBP1065-2 · replaces CBP1065-2 · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR KAF175B1C · replaces KAF175B1C · 777-200 SERIES, 777-200LR SERIES, 777-300 SERIES
2017-06-01CONTACTOR KAF501B10C · replaces KAF501B10C · 777-200 SERIES, 777-200LR SERIES, 777-300SERIES
2006-11-08Contactor D18ZZC · replaces Bombardier P/N: D18ZZA · CL-600-2B19 Regional Jet Series 200
2006-11-08Contactor D7GSZ · replaces Bombardier P/N: D7GRZ · CL-600-2B19 Regional Jet Series 200
2004-04-18Power Relais SD167A · replaces Eurocopter SD167A · MBB-BK 117C-2
2000-04-23Contactor B-461D-1 · replaces 5D0271-2 · MD-11, MD-11F
1999-11-02Relay, Power, Non-Latch BP494A · replaces D5910914 · 717-200
1994-11-27Contactor SPST Side Stable 100 Amp, 28 VDC NN-307A · replaces SAAB 9303273-001 · 2000
1994-11-27Contactor SPDT, Side-Stable, 400 Hz, 28 VDC 50 Amp D-7GRZ · replaces Bombardier D-7GRZ · CL-600-2B19
1994-11-27Contactor - DC SPDT, 60 Amps NN-233C · replaces Bombardier NN-233C · CL-600-2B19
1994-11-27Contactor - DC SPDT, 100 Amps NN-449B · replaces Bombardier NN-449B · CL-600-2B19
1994-11-27Remote Power Controller, 3 PST 115/208 VAC, 100A RA-3100D · replaces SAAB 9303704-002 · 2000
1994-11-27Contactor 3 PDT, Center-Off 50 Amp, 400 Hz D-18ZZA · replaces Bombardier D-18ZZA · CL-600-2B19
1994-11-27Remote Power Controller, 3 PST 115/208 VAC, 70A RA-3100F · replaces SAAB 9309122-001 · 2000
1994-03-28Relay - 60 Amp., 115 VAC, 400Hz or 28VDC BH-316 · replaces Boeing 10-61445-20 · 747-100, -200, -300
1994-03-28Relay - 25 Amp., 115 VAC, 400Hz or 28VDC BH-315 · replaces Boeing 10-61445-13 · 747-100, -200, -300
1994-03-28Relay - 50 Amp., 115 VAC, 400Hz or 28VDC BH-316A · replaces Boeing 10-61445-21 · 747-100, -200, -300
1994-03-28Contactor 3PDT, Side Stable 120 Amp, 115/200V, 400Hz B-233R · replaces Boeing B-233R · 747-400
1994-03-21Relay Undervoltage ac 3 Phase - Lowest of 3 E-316C · replaces Boeing E-316C · 747-100, -200, -300
1994-01-20Contactor Intermittent Duty 300 Amps, 28 Volts A-770WA-3 · replaces McDonnell Douglas A-770WA-3 · DC-10-10, -10F, -15
1994-01-20Contactor - 3 PDT Sidestable B-209E · replaces McDonnell Douglas B-209E · DC-10-10, -10F, -15
1994-01-20Contactor - 3PDT Sidestable 50 AMP, 115/200 VAC, 400 Hz D-7GR · replaces McDonnell Douglas D-7GR · DC-10-10, -10F, -15
1994-01-20Contactor - 3PST NO Sidestable 50 AMP, 115/200 VAC, 400Hz DR-7VC · replaces McDonnell Douglas DR-7VC · DC-10-10, -10F, -15
1994-01-20Contactor - AC Power 250 AMP, 3 PST NO BR-125BC · replaces McDonnell Douglas BR-125BC · DC-10-10, -10F, -15
1994-01-20AC Power Contactor 175-250A TPDT Center Off B-124VM · replaces McDonnell Douglas B-124VM · DC-10-10, -10F, -15
1994-01-20Contactor - SPDT Center Off 100 AMP, 28 VDC D-31BAA · replaces McDonnell Douglas D-31BAA · DC-10-10, -10F, -15
1994-01-20Contactor SPST NO Magnetic Latching 200 Amps, 28 VDC A-1074 · replaces McDonnell Douglas A-1074 · DC-10-10, -10F, -15
1994-01-20Contactor SPST Sidestable 300 Amps, 28 VDC A-770W · replaces McDonnell Douglas A-770W · DC-10-10, -10F, -15
1994-01-20Contactor - 3PDT Center Off 50 AMP, 115/200 VAC 400Hz D-18 · replaces McDonnell Douglas D-18 · DC-10-10, -10F, -15
1994-01-20Contactor - 3PDT Side Stable 100 AMP 115/200 Volts 400 Hz D-25BAA · replaces McDonnell Douglas D-25BAA · DC-10-10, -10F, -15
1994-01-20Contactor SPST Sidestable 300 Amps, 28 VDC AR-770W · replaces McDonnell Douglas AR-770W · DC-10-10, -10F, -15
1994-01-20Contactor - 3 PST NO 350 AMP 120/208V 400Hz B-429CA · replaces McDonnell Douglas B-429CA · MD-11, -11F
1994-01-20Contactor - 3PDT Center Off 100 AMP, 115 Volts, 400 Hz D-31TFA · replaces McDonnell Douglas D-31TFA · DC-10-10, -10F, -15
1993-10-20Relay Current Ind. Q-50AB-1 · replaces Hartman Elect. Q-50AB-1 · 3101, 3201, 3101
1993-10-20Relay Overvoltage with Time Delay E-311TS · replaces Hartman Elect. E-311TS · BAe.125-800
1993-10-20Contactor - 3PDT Center off Hermietically Sealed DHR-18-1 · replaces Hartman Elect. DHR-18-1 · F.28 Mark 4000, 0100
1993-10-20Relay E-329E · replaces Hartman Elect. E329E · 737-200, -300, -400
1993-10-20KLC/KBT A-703E · replaces Hartman Elect. A-703E · 228
1993-10-20Relay Current ACR-739AG-2 · replaces Hartman Elect. ACR-739AG-2 · SD3-60
1993-10-20Contactor DC SPST 100 Amps N-419S · replaces Hartman Elect. N-419S · BAe.125-700
1993-10-20Contactor - 2 PST NO 400 28 VDC A-1148B · replaces Hartman Elect. A-1148B · ATR42, ATR72
1993-10-20KSR 400 Amp 28 V. A-703FB · replaces Hartman Elect. A-703FB · SD3-30, -60
1993-10-20Contactor Series Paralleling 2 SPDT A-882DL · replaces Hartman Elect. A-882DL · CASA) (C-212
1993-10-20Contactor 3 PST NO 350 Amp 120/208V 400 Hz B-429C · replaces McDonnell Douglas 5D0270-1 · MD-11, -11F
1993-10-20Cutout/Reverse Current A-700AAP · replaces Hartman Elect. A-700AAP · SC-7 Series 2 & 3
1993-10-20Contactor - 3PDT Center off 60 Amp 115/200V 400 Hz B-227 · replaces Hartman Elect. B-227 · F.28 Mark 4000
1993-10-20Contactor Intermittent Duty 300 Amp 28 V A-770WA-2 · replaces Hartman Elect. A-770WA-2 · DC-9-11, -12, -13
1993-10-20Relay Sensing E-329H · replaces Hartman Elect. E-329H · F.28 Mark 0100
1993-10-20Relay Current Ind. Q-50BB · replaces Hartman Elect. Q-50BB · SD3-60
1993-10-20Contactor SPST NO 400 Amp 28 V A-703S · replaces Hartman Elect. A-703S · BAe.125-700
1993-10-20Contactor B-451 · replaces Hartman Elect. B-451 · 737-200, -300, -400
1993-10-20Contactor 3 PDT Sidestable B-499 · replaces Hartman Elect. B-499 · MD-11, -11F
1993-10-20Contactor D-7AC · replaces Hartman Elect. D-7AC · 757
1993-10-20Contactor 60 Amp 115/208 400Hz 3 PDT Sidestable Single Break DH-7BC · replaces Hartman Elect. DH-7-BC · 737-200, -300, -400
1993-10-20Contactor A-1077DD · replaces Hartman Elect. A-1077DD · 757, 767
1993-10-20Contactor 2PDT Sidestable B-499A · replaces McDonnell Douglas 5D0272-1 · MD-11, -11F
1993-10-20Contactor Intermittent Duty 300 Amp 28 V A-770WA-3 · replaces Hartman Elect. A-770WA-3 · DC-9-11, -12, -13
1993-10-20Contactor B-430-1 · replaces Boeing S281T004-1 · 757, 767
1993-10-20Relay Neg. Seq. Sensing E-107B · replaces Boeing 10-3263 · 707, 720
1993-10-20Relay AC Current Sensor QR-50V · replaces Hartman Elect. QR-50V · 340A, 340B
1993-10-20Monitor ext. Pwr. B-188MA-1 · replaces Hartman Elect. B-188MA-1 · DC-9-11, -12, -13
The first 80 of 164. All part makers.
Source: FAA Dynamic Regulatory System (type certificate data sheets, supplemental type certificates, parts manufacturer approvals, technical standard order authorisations). An organisation's name is as the FAA spelled it on each record; related spellings are separate pages.