1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. 2. The FAA amends § 39.13 by adding the following new airworthiness directive: 2022-04-07 General Electric Company: Amendment 39-21949; Docket No. FAA-2022-0101; Project Identifier AD-2021-01456-E. (a) Effective Date This airworthiness directive (AD) is effective March 9, 2022. (b) Affected ADs None. (c) Applicability This AD applies to all General Electric Company (GE) GEnx-1B64, GEnx-1B64/P1, GEnx-1B64/P2, GEnx-1B67, GEnx-1B67/P1, GEnx-1B67/P2, GEnx-1B70, GEnx-1B70/75/P1, GEnx-1B70/75/P2, GEnx-1B70/P1, GEnx-1B70/P2, GEnx-1B70C/P1, GEnx-1B70C/P2, GEnx-1B74/75/P1, GEnx-1B74/75/P2, GEnx-1B76/P2, GEnx-1B76A/P2, GEnx-2B67, GEnx-2B67B, and GEnx-2B67/P model turbofan engines with: (1) A fuel metering unit (FMU) VIN 8062-1094 part number (P/N) 2122M20P07, VIN 8062-1176 P/N 2122M20P08, VIN 8062-1106 P/N 2459M17P01, or VIN 8062-1177 P/N 2459M17P02, installed; and (2) An FMU having a serial number (S/N) identified in Paragraph 4, Appendix A, Table 1, of either GE GEnx-1B Service Bulletin (SB) 73-0100 R00, dated December 3, 2021 (GEnx-1B SB 73-0100), or GE GEnx-2B SB 73-0092 R00, dated December 3, 2021 (GEnx-2B SB 73-0092). (d) Subject Joint Aircraft System Component (JASC) Code 7320, Fuel Controlling System. (e) Unsafe Condition This AD was prompted by an in-flight shutdown (IFSD) of an engine and subsequent investigation by the manufacturer that revealed an improperly torqued FMU bypass valve (BPV) plug. The FAA is issuing this AD to prevent fuel system leakage from the FMU. The unsafe condition, if not addressed, could result in the loss of engine thrust control, IFSD, and reduced control of the aircraft. (f) Compliance Comply with this AD within the compliance times specified, unless already done. (g) Required Actions (1) Within 150 flight cycles after the effective date of this AD, perform either an on-wing or off-wing shim check inspection using a 0.005 inch feeler gauge of the FMU BPV plug to verify the FMU BPV plug is properly installed using the Accomplishment Instructions, paragraph 3.A.(4) or paragraph 3.B.(3), of GEnx-1B SB 73-0100 (for GEnx-1B models) or the Accomplishment Instructions, paragraph 3.A.(4) or paragraph 3.B.(3), of GEnx-2B SB 73-0092 (for GEnx-2B models), as applicable. Perform the shim check inspection on any flat side of the FMU BPV plug. (2) If, during the inspection required by paragraph (g)(1) of this AD, the 0.005 inch feeler gauge can fit between the FMU BPV plug and the FMU housing on the flat side, before further flight, remove the FMU and replace with an FMU eligible for installation. (h) Definitions For the purpose of this AD, an "FMU eligible for installation" is: (1) An FMU having a S/N that is not identified in Paragraph 4, Appendix A, Table 1, of GEnx-1B SB 73-0100 or GEnx-2B SB 73-0092; (2) An FMU having a S/N identified in Paragraph 4, Appendix A, Table 1, of GEnx-1B SB 73-0100 or GEnx-2B SB 73-0092 that passes the shim check inspection required by paragraph (g)(1) of this AD; or (3) An FMU having a S/N identified in Paragraph 4, Appendix A, Table 1, of GEnx-1B SB 73-0100 or GEnx-2B SB 73-0092 that fails the shim check inspection required by paragraph (g)(1) of this AD but has had the packing of the FMU BPV plug replaced per the Accomplishment Instructions, paragraph 3.C. of GEnx-1B 73-0100 or GEnx-2B 73-0092. (i) Alternative Methods of Compliance (AMOCs) (1) The Manager, ECO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to the attention of the person identified in paragraph (j) of this AD and email to:
[email protected]. (2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. (j) Related Information For more information about this AD, contact Alexei Marqueen, Aviation Safety Engineer, ECO Branch, FAA, 1200 District Avenue, Burlington, MA 01803; phone: (781) 238-7178; email:
[email protected]. (k) Material Incorporated by Reference (1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. (2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. (i) General Electric Company (GE) GEnx-1B Service Bulletin (SB) 73-0100 R00, dated December 3, 2021. (ii) GE GEnx-2B SB 73-0092 R00, dated December 3, 2021. (3) For service information identified in this AD, contact General Electric Company, 1 Neumann Way, Cincinnati, OH 45215; phone: (513) 552-3272; email:
[email protected]; website: https://www.ge.com. (4) You may view this service information at FAA, Airworthiness Products Section, Operational Safety Branch, 1200 District Avenue, Burlington, MA 01803. For information on the availability of this material at the FAA, call (817) 222-5110. (5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, email:
[email protected], or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html. Issued on February 15, 2022. Ross Landes, Deputy Director for Regulatory Operations, Compliance & Airworthiness Division, Aircraft Certification Service. [FR Doc. 2022-03787 Filed 2-17-22; 11:15 am]BILLING CODE 4910-13-P