Medical Stretcher
No failure report names the medical stretcher. 5 FAA approvals let 2 companies make a replacement medical stretcher, Aviation Fabricators holding the most (4).
Approved replacement parts 5 parts manufacturer approvals
A parts manufacturer approval (PMA) lets a company other than the aircraft's maker make a medical stretcher and sell it as an approved part for the models named. These are the companies holding such approvals for a medical stretcher:
For these models most: Mitsubishi MU-300 (3), Beechcraft 400 Beechjet (2).
| Maker | Part | Replaces | Fits | Granted | Status |
|---|---|---|---|---|---|
| Aviation Fabricators | LH Medical Stretcher 32-0221K-101 | Modification Part | Raytheon Beechjet 400, 400A, 400T With STC... | 2004-03-10 | current |
| Aviation Fabricators | LH Medical Stretcher 32-0221K-101 | Modification Part | Mitsubishi MU-300 With STC SA3894NM installed | 2004-03-10 | current |
| Aviation Fabricators | RH Medical Stretcher 32-0221K-102 | Modification Part | Raytheon Beechjet 400, 400A, 400T With STC... | 2004-03-10 | current |
| Aviation Fabricators | RH Medical Stretcher 32-0221K-102 | Modification Part | Mitsubishi MU-300 With STC SA3894NM installed | 2004-03-10 | current |
| Branson Aircraft CORP | Medical Stretcher Dwg 51A360 | Modification Part | Beech Raytheon) (400, MU-300 | 1991-10-07 | current |
Sources: the FAA's service difficulty reports since 1995 (a report is a part that failed and was fixed, as filed by an airline, repair station or owner; the count shows reporting as much as reliability) and the parts manufacturer approvals in the FAA's Dynamic Regulatory System. The part name is the reporters' and the approval holders' own words, reduced to the first plain words so that spellings meet.