2021-10-22: Fuel

FAA order 2021-10-22 is an airworthiness directive in force since July 6, 2021. The FAA's subject line: Fuel. It names Bombardier BD-700 Global Express, 5000 and 6000: about 662 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: fuel system.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Bombardier Inc.
Models
BD-700-1A10
On this site
Bombardier BD-700 Global Express, 5000 and 6000 662 registered

Dates and paperwork

In force since
July 6, 2021
Published
June 1, 2021 (signed May 6, 2021)
Docket
FAA-2021-0030
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

The FAA is adopting a new airworthiness directive (AD) for certain Bombardier, Inc., Model BD-700-1A10 airplanes. This AD was prompted by a report indicating that during installation, a fuel pipe bracket assembly on the intermediate rib in the center fuel tank was mislocated, resulting in an offset between the fitting assembly and the refuel/defuel tube assembly. This AD requires modification of the fuel pipe bracket assembly, including all related investigative actions and corrective actions, if necessary; and performing an operational test of the refuel and defuel system. The FAA is issuing this AD to address the unsafe condition on these products.

The order itself the regulatory text, as published

Show the full text (5,659 characters)
Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive: \n\n2021-10-22 Bombardier, Inc.: Amendment 39-21555; Docket No. FAA- 2021-0030; Project Identifier MCAI-2020-01395-T. \n\n(a) Effective Date \n\n\n\tThis airworthiness directive (AD) is effective July 6, 2021. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to Bombardier, Inc., Model BD-700-1A10 airplanes, certificated in any category, serial numbers 9657 through 9844 inclusive. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 28, Fuel. \n\n(e) Reason \n\n\n\tThis AD was prompted by a report indicating that duringinstallation, a fuel pipe bracket assembly on the intermediate rib in the center fuel tank was mislocated, resulting in an offset between the fitting assembly and the refuel/defuel tube assembly. The FAA is issuing this AD to address the offset, which could cause a preload on the fuel pipes and reduce their ability to absorb shock or vibration-induced loads, making the tube and clamp more prone to stress corrosion cracking. This could lead to failure of the coupling and the bracket and p-clamp assembly, resulting in fuel leakage and loss of electrical bonding between fuel pipes, and lightning-induced sparking that could induce fuel ignition. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Inspection and Corrective Action \n\n\n\tWithin 30 months after the effective date of this AD: Perform a modification of the fuel pipe bracket assembly and refuel tube assembly; do all related investigative actions and applicable corrective actions; and perform an operational test of the refuel and defuel system; in accordance with paragraphs 2.B. and 2.C. of the Accomplishment Instructions of Bombardier Service Bulletin 700- 28-6006, dated June 1, 2020. All related investigative and corrective actions must be done before further flight. \n\n(h) Other FAA AD Provisions \n\n\n\tThe following provisions also apply to this AD: \n\t(1) Alternative Methods of Compliance (AMOCs): The Manager, New York ACO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or responsible Flight Standards Office, as appropriate. If sending information directly to the manager of the certification office, send it to ATTN: Program Manager, Continuing Operational Safety, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; fax 516-794-5531. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the responsible Flight Standards Office. \n\t(2) Contacting the Manufacturer: For any requirement in this AD to obtain instructions from a manufacturer, the instructions must be accomplished using a method approved by the Manager, New York ACO Branch, FAA; or Transport Canada Civil Aviation (TCCA); or Bombardier, Inc.'s TCCA Design Approval Organization (DAO). If approved by the DAO, the approval must include the DAO-authorized signature. \n\n(i) Related Information \n\n\n\t(1) Refer to Mandatory Continuing Airworthiness Information (MCAI) TCCA AD CF-2020-37, dated October 9, 2020, for related information. This MCAI may be found in the AD docket on the internet at https://www.regulations.gov by searching for and locating Docket No. FAA-2021-0030. \n\t(2) For more information about this AD, contact Siddeeq Bacchus, Aerospace Engineer, Mechanical Systems and Administrative ServicesSection, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7362; fax 516-794-5531; email [email protected]. \n\n(j) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise. \n\t(i) Bombardier Service Bulletin 700-28-6006, dated June 1, 2020. \n\t(ii) (Reserved) \n\t(3) For service information identified in this AD, contact Bombardier, Inc., 400 Cote-Vertu Road West, Dorval, Quebec H4S 1Y9, Canada; telephone 514-855-5000; fax 514-855- 7401; email [email protected]; internet https://www.bombardier.com. \n\t(4) You may view this service information at the FAA, Airworthiness Products Section, Operational Safety Branch, 2200 South 216th St., Des Moines, WA. For information on the availability of this material at the FAA, call 206-231-3195. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, email [email protected], or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html. \n\n\n\tIssued on May 6, 2021. Gaetano A. Sciortino, Deputy Director for Strategic Initiatives, Compliance & Airworthiness Division, Aircraft Certification Service. (FR Doc. 2021-11427 Filed 5-28-21; 8:45 am) BILLING CODE 4910-13-P

Related safety bulletins advice on the same designs, not orders

2021-09-16AIR-21-15R1 · Navigation System
2021-08-26AIR-21-15 · Navigation System
2014-11-06NM-15-02 · Cabin Equipment/Furnishings
2011-05-17NM-11-34 · Doors: Passenger/Crew Doors, Tensator Springs of the Door Actuator

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 20, 2026. Connections as data: /graph/directive/2021-10-22.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.