Show the full text (4,029 characters)
98-18-08 BOMBARDIER INC. (formerly deHavilland, Inc.): Amendment 39-10724; Docket No. 97-CE-120-AD.
Applicability: Model (Otter) DHC-3 airplanes, all serial numbers, certificated in any category, that have been modified by A.M. Luton Supplemental Type Certificate (STC) No. SA3777NM.
NOTE 1: This AD applies to each airplane identified in the preceding applicability provision that has the applicable STC incorporated, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (c) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.
Compliance: Required within the next 14 calendar months after the effective date of this AD, unless already accomplished.
To prevent electrical system failure caused by inadequate electrical system requirements, which could result in the loss of the engine instruments or a possible electrical fire in the airplane's cockpit, accomplish the following:
(a) Replace the voltage regulator and the voltage-ammeter gauge, and modify the auxiliary bus systems in accordance with A.M. Luton Electrical System Schematic, Drawing 20075, Rev. G and E, Sheets 1, 2, and 3, dated May 15, 1998, which is referenced in A.M. Luton Service Information Letter No. SA-SIL-98-11-03, "Electrical Systems", Revision A, dated May 15, 1998.
(b) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a locationwhere the requirements of this AD can be accomplished.
(c) An alternative method of compliance or adjustment of the compliance time that provides an equivalent level of safety may be approved by the Manager, Seattle Aircraft Certification Office (ACO), FAA, 1601 Lind Avenue, SW, Renton, Washington 98055-4056. The request shall be forwarded through an appropriate FAA Maintenance Inspector, who may add comments and then send it to the Manager, Seattle ACO.
NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from Seattle ACO.
(d) Questions or technical information related to A.M. Luton Electrical System Schematic, Drawing 20075, Rev. G and E, Sheets 1, 2, and 3, dated May 15, 1998, and A.M. Luton Service Information Letter No. SA-SIL-98-11-03, "Electrical Systems", Revision A, dated May 15, 1998, should be directed to A.M. Luton, 3025 Eldridge Ave., Bellingham, WA 98226; telephone: (360) 671-7817, facsimile: (360) 671-7820. This service information may be examined at the FAA, Central Region, Office of the Regional Counsel, Room 1558, 601 E. 12th Street, Kansas City, Missouri 64106.
(e) The replacements and modifications required by this AD shall be done in accordance with A.M. Luton Electrical System Schematic, Drawing 20075, Rev. G and E, Sheets 1, 2, and 3, dated May 15, 1998, which is referenced in A.M. Luton Service Information Letter No. SA-SIL-98-11-03, "Electrical Systems", Revision A, dated May 15, 1998. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from A.M. Luton, 3025 Eldridge Ave., Bellingham, WA 98226. Copies may be inspected at the FAA, Central Region, Office of the Regional Counsel, Room 1558, 601 E. 12th Street, Kansas City, Missouri, or at the Office of the Federal Register, 800 North Capitol Street, NW, suite 700, Washington, DC.(f) This amendment becomes effective on October 10, 1998.