Show the full text (3,335 characters)
98-17-08 FOKKER AIRCRAFT B.V.: Amendment 39-10710; Docket 97-NM-287-AD.
Applicability: Model F.28 Mark 1000, F.28 Mark 2000, F.28 Mark 3000, and F.28 Mark 4000 series airplanes; all serial numbers; certificated in any category.
NOTE 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (b) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it.
Compliance: Required as indicated, unless accomplished previously.
To prevent inadvertent closure of the fire shut-off valves due to ineffective or absent sealwires, which could result in in-flight engine shutdown, accomplish the following:
(a) Within 30 days after the effective date of this AD, perform an inspection of the engine fire shut-off system to detect any discrepancy in the sealwire of the fireguards, in accordance with Part I of the Accomplishment Instructions of Fokker Service Bulletin F28/76-20, dated January 1, 1979. If any discrepancy is detected, prior to further flight, repair it in accordance with the service bulletin. Thereafter, repeat the inspection at intervals not to exceed 3,000 flight hours.
(b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, International Branch, ANM-116, FAA, Transport Airplane Directorate. Operators shall submit their request throughan appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, International Branch, ANM-116.
NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the International Branch, ANM-116.
(c) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished.
(d) The actions shall be done in accordance with Fokker Service Bulletin F28/76-20, dated January 1, 1979. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Fokker Services B.V., Technical Support Department, P.O. Box 75047, 1117 ZN Schiphol Airport, the Netherlands. Copies may be inspected at the FAA, TransportAirplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.
NOTE 3: The subject of this AD is addressed in Dutch airworthiness directive BLA No. 1979-007/2 (A), dated February 28, 1997.
(e) This amendment becomes effective on September 18, 1998.