Show the full text (4,682 characters)
94-01-14 CANADAIR LIMITED: Amendment 39-8796. Docket 93-NM-215-AD.
Applicability: Model CL-600-2B19 (Regional Jet) series airplanes, serial numbers 7003 through 7028 inclusive, certificated in any category.
Compliance: Required as indicated, unless accomplished previously.
To prevent loss of engine oil and subsequent engine shutdown during flight, accomplish the following:
(a) Within 14 days after the effective date of this AD, add the following to the Limitations Section of the FAA-approved Airplane Flight Manual (AFM). This may be accomplished by inserting a copy of this AD in the AFM. This AFM revision may be removed from the AFM if the optional terminating action specified in paragraph (d) of this AD is accomplished.
"Both integrated drive generators must be operational for dispatch. NOTE: This overrides the current applicable Master Minimum Equipment List (MMEL) requirement."
(b) For airplanes on which the IDG has been disconnected during flight: Prior to further flight, inspect the integrated drive generator (IDG) oil level in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-015, Revision 'A,' dated December 1, 1993.
(1) If the oil level is on or below the "ADD" mark, prior to further flight, replace the IDG with a serviceable unit in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-015, Revision 'A,' dated December 1, 1993, or modify the IDG in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-016, Revision 'A,' dated December 3, 1993.
(2) If the oil level is above the "ADD" mark, replace the IDG with a serviceable unit in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24- 015, Revision 'A,' dated December 1, 1993, or modify the IDG in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-016, Revision 'A,' dated December 3, 1993. The action shall be accomplished prior to further flight, except that a special flight permit may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location in order to comply with the requirements of this paragraph, provided that the IDG remains disconnected.
(c) Within 14 days after the effective date of this AD, inspect the IDG oil level in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-015, Revision 'A,' dated December 1, 1993. If the oil level is on or below the "ADD" mark, prior to further flight, replenish with oil in accordance with the service bulletin. Repeat the inspection thereafter at intervals not to exceed 30 hours time-in-service.
(d) Modification of the IDG in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-016, Revision 'A,' dated December 3, 1993, constitutes terminating action for the requirements of this AD. If this modification is accomplished, the AFM revision required by paragraph (a) of this AD shall be removed from the AFM.(e) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, New York Aircraft Certification Office (ACO), ANE-170, FAA, Engine and Propeller Directorate. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, New York ACO.
NOTE: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the New York ACO.
(f) Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished.
(g) The actions shall be done in accordance with Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-015, Revision 'A,' dated December 1, 1993, and Canadair Regional Jet Alert Service Bulletin S.B.A601R-24-016, Revision 'A,' dated December 3, 1993. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. Copies may be obtained from Bombardier, Inc., Bombardier Regional Aircraft Division, Garratt Boulevard, Downsview, Ontario M3K 1Y5, Canada. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the FAA, Engine and Propeller Directorate, New York Aircraft Certification Office, 181 South Franklin Avenue, Valley Stream, New York; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC.
(h) This amendment becomes effective on January 28, 1994.