eFlight
FAA orders · airworthiness directive · current

93-09-02: Hydraulic Fire Shut Off Valve Actuator

FAA order 93-09-02 is an airworthiness directive in force since June 9, 1993. The FAA's subject line: Hydraulic Fire Shut Off Valve Actuator. It names Airbus A300: about 120 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Airbus
Models
A300 B2-1A, A300 B2-1C, A300 B2-203, A300 B2K-3C, A300 B4-103, A300 B4-203, A300 B4-2C, A300 B4-601, A300 B4-603, A300 B4-605R, A300 B4-620, A300 B4-622R, A300 F4-605R, A300 F4-622R, A310-203, A310-221, A310-222, A310-304, A310-322, A310-324, A310-325
On this site
Airbus A300 120 registered

Dates and paperwork

In force since
June 9, 1993
Docket
92-NM-226-AD
Status
Current
The FAA's document
Read the order on the FAA's site

The order itself the regulatory text, as published

Show the full text (3,852 characters)
93-09-02 AIRBUS INDUSTRIE: Amendment 39-8569. Docket 92-NM-226-AD. Applicability: Model A300, A310, and A300-600 series airplanes, as listed in Airbus Industrie All Operator Telex (AOT) 29-07, dated August 28, 1992; airplanes, certificated in any category. Compliance: Required as indicated, unless accomplished previously. To prevent jamming of the hydraulic fire shut off valve (FSOV) actuator, which could result in the inability to isolate hydraulic fluid from an engine fire, accomplish the following: (a) For airplanes having any hydraulic FSOV that has not ever been functionally tested in accordance with Maintenance Planning Document (MPD) Task Number 29-11-33-0503-1 (for Model A300 series airplanes) or MPD Task Number 29-11-33-01-1 (for Model A310 and A300-600 series airplanes): Within 450 hours time-in-service after the effective date of this AD, perform a one-time operational test to detect potential bearing failure of the electric motor that drives thehydraulic FSOV actuator, and to detect FSOV malfunction, in accordance with Airbus Industrie All Operator Telex (AOT) 29-07, dated August 28, 1992. (1) If any FSOV fails the operational test, prior to further flight, replace that FSOV in accordance with the AOT. (2) If a FSOV passes the operational test, no further action is necessary for that FSOV. (b) For airplanes having any hydraulic FSOV that has been functionally tested only once in accordance with MPD Task Number 29-11-33-0503-1 (for Model A300 series airplanes) or MPD Task Number 29-11-33-01-01 (for Model A310 and A300-600 series airplanes): Within 900 hours time-in-service after the effective date of this AD, perform a one-time operational test to detect potential bearing failure of the electric motor that drives the hydraulic FSOV actuator, and to detect FSOV malfunction, in accordance with Airbus Industrie All Operator Telex (AOT) 29-07, dated August 28, 1992. (1) If any FSOV fails the operational test, prior tofurther flight, replace that FSOV in accordance with the AOT. (2) If a FSOV passes the operational test, no further action is necessary for that FSOV. (c) For airplanes having any hydraulic FSOV that has been functionally tested two or more times in accordance with MPD Task Number 29-11-33-0503-1 (for Model A300 series airplanes) or MPD Task Number 29-11-33-01-01 (for Model A310 and A300-600 series airplanes): No further action is required by this AD. (d) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Standardization Branch, ANM-113, FAA, Transport Airplane Directorate. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Standardization Branch, ANM-113. NOTE: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Standardization Branch, ANM-113. (e) Special flight permits may be issued in accordance with FAR 21.197 and 21.199 to operate the airplane to a location where the requirements of this AD can be accomplished. (f) The tests shall be done in accordance with Airbus Industrie All Operator Telex (AOT)-29-07, dated August 28, 1992. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. Copies may be obtained from Airbus Industrie, 1 Rond Point Maurice Bellonte, 31707 Blagnac Cedex, France. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. (g) This amendment becomes effective on June 9, 1993.

Related safety bulletins advice on the same designs, not orders

2019-02-19NE-19-03 · Escape Slide Maintenance Tasks and Intervals - JASC 2565
2008-12-11NM-09-03 · Engine Fuel and Control - Implementing Fuel Tank System Airworthiness Limitations
2008-07-02NM-08-31 · Equipment/Furnishings: Non-Textile Floors
2006-12-11SW-07-13 · Oxygen Reserve Cylinder
2006-07-27NM-06-57 · Reports of damage to airplanes and to property on the ground caused by blue or clear ice falling from airplanes.

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/93-09-02.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.