Show the full text (6,900 characters)
The Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive: \n\n2021-03-02 General Electric Company: Amendment 39-21405; Docket No. FAA-2020-0371; Project Identifier AD-2019-00124-E. \n\n(a) Effective Date \n\n\n\tThis airworthiness directive (AD) is effective March 31, 2021. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to General Electric Company (GE) CF6-80C2A1, CF6-80C2A2, CF6-80C2A3, CF6-80C2A5, CF6-80C2A5F, CF6-80C2A8, CF6- 80C2B1, CF6-80C2B1F, CF6-80C2B2, CF6-80C2B2F, CF6-80C2B4, CF6- 80C2B4F, CF6-80C2B5F, CF6-80C2B6, CF6-80C2B6F, CF6-80C2B6FA, CF6- 80C2B7F, CF6-80C2B8F, and CF6-80C2D1F model turbofan engines that underwent an engine shop visit before November 1, 2018, and with accessory gearbox (AGB) adapter hydromechanical unit (HMU)/main engine control (MEC) idler adapter with part number (P/N) 9395M78G01, P/N 9395M78G02, P/N 9395M78G04, P/N 9395M78G05, P/N 9395M78G08, or P/N 9395M78G10, installed. \n\n(d) Subject \n\n\n\tJoint Aircraft System Component (JASC) Code 7321, Fuel Control/ Turbine Engines. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by failure of the HMU/MEC on the AGB assembly. The FAA is issuing this AD to prevent failure of the HMU/ MEC. The unsafe condition, if not addressed, could result in engine fire and damage to the airplane. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Required Actions \n\n\n\t(1) Perform a shim check of the HMU/MEC idler adapter inserts using paragraph 3.B.(1) of GE CF6-80C2 Service Bulletin (SB) 72-1577 R01, dated August 16, 2019 (the SB), within 1,200 flighthours (FHs) after the effective date of this AD. \n\t(2) Thereafter, perform a repetitive shim check of the HMU/MEC idler adapter inserts using paragraph 3.B.(1) of the SB within every 1,200 FHs since the last shim check. \n\t(3) If any HMU/MEC idler adapter insert fails the shim check required by paragraph (g)(1) or (2) of this AD, perform the following before further flight: \n\t(i) Retorque the bolts at each bolt location that failed the shim check using paragraph 3.B.(1)(c) of the SB. \n\t(ii) Perform the shim check again using paragraph 3.B.(1)(b) of the SB. If the shim check fails, perform the terminating action required by paragraph (h) of this AD. \n\n((Page 11116)) \n\n(h) Terminating Action \n\n\n\tAs a terminating action to the requirements of paragraph (g) of this AD, perform the following: \n\t(1) Do a protrusion check at all eight bolt locations using paragraph 3.C.(3) of the SB. \n\t(2) Do a pull-out test at all eight bolt locations using paragraph 3.C.(4) of the SB. \n\t(3) Ifthe inserts on the HMU/MEC idler adapter fail the protrusion check or pull-out test required by paragraph (h)(1) or (2) of this AD, replace the inserts using paragraph 3.C.(5) of the SB. After replacement of the inserts is accomplished, the requirements of this AD have been met and no further action is required. \n\t(4) If the inserts on the HMU/MEC idler adapter pass both the protrusion check and the pull-out test required by paragraphs (h)(1) and (2) of this AD, the requirements of this AD have been met and no further action is required. \n\n(i) Credit for Previous Actions \n\n\n\t(1) You may take credit for any shim check of the HMU/MEC idler adapter required by paragraph (g) of this AD if you performed this shim check before the effective date of this AD using GE CF6-80C2 SB 72-1577 R00, dated October 31, 2018. \n\t(2) You may take credit for the terminating action required by paragraph (h) of this AD if you performed this action before the effective date of this AD using GE CF6-80C2SB 72-1577 R00, dated October 31, 2018. \n\n(j) Definition \n\n\n\tFor the purpose of this AD, an ''engine shop visit'' is the induction of an engine into the shop for maintenance involving the separation of pairs of major mating engine case flanges, except separation of engine flanges solely for the purposes of transportation of the engine without subsequent maintenance, which does not constitute an engine shop visit. \n\n(k) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, ECO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to the attention of the person identified in Related Information. You may email your request to: ANE-AD-AMOC@faa.gov. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\n(l) Related Information \n\n\n\tFor more information about this AD, contact Kevin M. Clark, Aviation Safety Engineer, ECO Branch, FAA, 1200 District Avenue, Burlington, MA 01803; phone: (781) 238-7088; fax: (781) 238-7199; email: kevin.m.clark@faa.gov. \n\n(m) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) General Electric Company (GE) CF6-80C2 Service Bulletin 72- 1577 R01, dated August 16, 2019. \n\t(ii) (Reserved) \n\t(3) For GE service information identified in this AD, contact General Electric Company,1 Neumann Way, Cincinnati, OH 45215; phone: (513) 552-3272; email: aviation.fleetsupport@ge.com. \n\t(4) You may view this service information at FAA, Airworthiness Products Section, Operational Safety Branch, 1200 District Avenue, Burlington, MA 01803. For information on the availability of this material at the FAA, call (781) 238-7759. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, email: fedreg.legal@nara.gov, or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html. \n\n\n\tIssued on January 21, 2021. Ross Landes, Deputy Director for Regulatory Operations, Compliance & Airworthiness Division, Aircraft Certification Service. (FR Doc. 2021-03606 Filed 2-23-21; 8:45 am) BILLING CODE 4910-13-P