Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2020-18-02 The Boeing Company: Amendment 39-21223; Docket No. FAA- 2016-6145; Product Identifier 2015-NM-056-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective November 10, 2020. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to The Boeing Company Model 747-400, -400D, and -400F series airplanes, certificated in any category, excluding the airplanes identified in paragraphs (c)(1) and (2) of this AD. \n\t(1) Airplanes equipped with a flammability reduction means (FRM) approved by the FAA as compliant with the fuel tank flammability reduction (FTFR) requirements of 14 CFR 25.981(b) or 26.33(c)(1). \n\t(2) Airplanes equipped with an ignition mitigation means (IMM) approved by the FAA as compliant with the FTFR requirements of 14 CFR 25.981(c) or 26.33(c)(2). \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 28, Fuel. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by the FAA's analysis of the Model 747 fuel system reviews conducted by the manufacturer. The FAA is issuing this AD to prevent ignition sources inside the center fuel tank, which, in combination with flammable fuel vapors, could result in a fuel tank explosion and consequent loss of the airplane. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Modification \n\n\n\tWithin 72 months after the effective date of this AD, modify the fuel quantity indicating system (FQIS) to prevent development of an ignition source inside the center fuel tank due to electricalfault conditions, using a method approved in accordance with the procedures specified in paragraph (i) of this AD. \n\n(h) Alternative Actions for Cargo Airplanes \n\n\n\tFor airplanes used exclusively for cargo operations: As an alternative to the requirements of paragraph (g) of this AD, do the actions specified in paragraphs (h)(1) and (2) of this AD. To exercise this alternative, operators must perform the first inspection required under paragraph (h)(1) of this AD within 6 months after the effective date of this AD. To exercise this alternative for airplanes returned to service after conversion of the airplane from a passenger configuration to an all-cargo configuration more than 6 months after the effective date of this AD, operators must perform the first inspection required under paragraph (h)(1) of this AD prior to further flight after the conversion. \n\t(1) Within 6 months after the effective date of this AD, record the existing fault codes stored in the FQIS processor and before further flight thereafter do a BITE check (check of built-in test equipment) of the FQIS, in accordance with the Accomplishment Instructions of Boeing Service Bulletin 747-28-2340, dated June 6, 2014. If any nondispatchable fault code is recorded prior to the BITE check or as a result of the BITE check, before further flight, do all applicable repairs and repeat the BITE check until a successful test is performed with no nondispatchable faults found, in accordance with the Accomplishment Instructions of Boeing Service Bulletin 747-28-2340, dated June 6, 2014. Repeat these actions thereafter at intervals not to exceed 750 flight hours. Modification as specified in paragraph (h)(2) of this AD does not terminate the repetitive BITE check requirement of this paragraph. \n\t(2) Within 72 months after the effective date of this AD, do the actions specified in paragraph (h)(2)(i) or (ii) of this AD. \n\t(i) Modify the airplane by separating FQIS wiring that runs between the FQIS processor and the center tank wing spar penetrations, including any circuits that might pass through a main fuel tank, from other airplane wiring that is not intrinsically safe using methods approved in accordance with the procedures specified in paragraph (i) of this AD. \n\t(ii) Do a general visual inspection for any damage to the FQIS wire bundle and all \n\n((Page 62990)) \n\napplicable repairs; and modify the airplane by separating FQIS wiring that runs between the FQIS processor and the center tank wing spar penetrations, including any circuits that might pass through a main fuel tank, from other airplane wiring that is not intrinsically safe; in accordance with the Accomplishment Instructions of Boeing Service Bulletin 747-28-2344, dated October 12, 2018. Do all applicable repairs before further flight. \n\n(i) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle ACO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to the attention of the person identified in paragraph (j)(1) of this AD. Information may be emailed to:
[email protected]. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) An AMOC that provides an acceptable level of safety may be used for any repair, modification, or alteration required by this AD if it is approved by The Boeing Company Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO Branch, FAA, to make those findings. To be approved, the repair method, modification deviation, or alteration deviation must meet the certification basis of the airplane, and the approval must specifically refer to this AD. \n\t(4) For service information that contains steps that are labeled as Required for Compliance (RC), the provisions of paragraphs (i)(4)(i) and (ii) of this AD apply. \n\t(i) The steps labeled as RC, including substeps under an RC step and any figures identified in an RC step, must be done to comply with the AD. If a step or substep is labeled ''RC Exempt,'' then the RC requirement is removed from that step or substep. An AMOC is required for any deviations to RC steps, including substeps and identified figures. \n\t(ii) Steps not labeled as RC may be deviated from using accepted methods in accordance with the operator's maintenance or inspection program without obtaining approval of an AMOC, provided the RC steps, including substeps and identified figures, can still be done as specified, and the airplane can be put back in an airworthy condition. \n\n(j) Related Information \n\n\n\t(1) For more information about this AD, contact Jon Regimbal, Aerospace Engineer, Propulsion Section, FAA, Seattle ACO Branch, 2200 South 216th St., Des Moines, WA 98198; phone and fax: 206-231- 3557; email:
[email protected]. \n\t(2) Service information identified in this AD that is not incorporated by reference is available at the addresses specified in paragraphs (k)(3) and (4) of this AD. \n\n(k) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Service Bulletin 747-28-2340, dated June 6, 2014. \n\t(ii) Boeing Service Bulletin 747-28-2344, dated October 12, 2018. \n\t(3) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Contractual & DataServices (C&DS), 2600 Westminster Blvd., MC 110 SK57, Seal Beach, CA 90740- 5600; telephone 562-797-1717; internet https://www.myboeingfleet.com. \n\t(4) You may view this service information at the FAA, Airworthiness Products Section, Operational Safety Branch, 2200 South 216th St., Des Moines, WA. For information on the availability of this material at the FAA, call 206-231-3195. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, email
[email protected], or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html. \n\n\n\tIssued on August 19, 2020. Gaetano A. Sciortino, Deputy Director for Strategic Initiatives, Compliance & Airworthiness Division, Aircraft Certification Service. (FR Doc. 2020-21996 Filed 10-5-20; 8:45 am) BILLING CODE 4910-13-P