Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2020-14-09 The Boeing Company: Amendment 39-21163; Docket No. FAA- 2020-0579; Product Identifier 2020-NM-009-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective July 15, 2020. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to all The Boeing Company Model 737-8 and 737-9 airplanes with an airworthiness certificate or export certificate of airworthiness issued on or before the effective date of this AD, certificated in any category. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 2810, Fuel storage.(e) Unsafe Condition \n\n\n\tThis AD was prompted by a report that Kathon FP 1.5 biocide, when used as a fuel additive and running through the engines, can lead to significant engine anomalies. The FAA is issuing this AD to prevent these anomalies, which could result in loss of thrust control on both engines because the fuel systems for both engines are likely to be similarly affected. Loss of thrust control on both engines could result in failure to climb on takeoff, a forced off- airport landing, or an unacceptably high flightcrew workload. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Removal of Kathon FP 1.5 Biocide \n\n\n\t(1) For airplanes identified in paragraphs (g)(1)(i) and (ii) of this AD: Before further flight, remove Kathon FP 1.5 biocide from the fuel tanks and engines, as applicable, in accordance with Boeing Multi-Operator Message MOM-MOM-20-0522-01B, dated June 24, 2020. \n\t(i) Airplanes that have operated for fewer than 30 flight cycles after the last treatment with Kathon FP 1.5 biocide. \n\n((Page 42692)) \n\n\n\t(ii) Airplanes having any engine where that engine has operated for fewer than 30 flight cycles after the last exposure to Kathon FP 1.5 biocide. \n\t(2) No action is required by paragraph (g) of this AD for the engines on which CFM confirmed via myCFM case response that the engines are operating as expected. \n\n(h) Fueling Placard Installation \n\n\n\tBefore further flight, install a placard with letters having a minimum height of 0.20 inch on white or light gray background containing the text ''DO NOT OPERATE ENGINE WITH KATHON\TM\ FP 1.5 BIOCIDE FUEL ADDITIVE'' on the interior area of the refuel access panel in a location that allows refueling personnel full view of the placard text when the access door is open. \n\n(i) AFM Revision for Fuel Additive Limitation \n\n\n\tBefore further flight, revise the Certificate Limitations section of the existing airplane flight manual (AFM) to include the information specified in figure 1 to paragraph (i) of this AD. This may be done by inserting a copy of this AD into the existing AFM. When a statement identical to that in figure 1 to paragraph (i) of this AD has been included in the general revisions of the existing Boeing 737 AFM, the general revisions may be inserted into the existing AFM, and the copy of this AD may be removed from the existing AFM. (GRAPHIC) (TIFF OMITTED) TR15JY20.010 \n\n(j) Special Flight Permit \n\n\n\tSpecial flight permits, as described in 14 CFR 21.197 and 21.199, are not allowed until the actions required by paragraph (g) of this AD have been accomplished. \n\n(k) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle ACO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to the attention of the person identified in paragraph (l) of this AD. Information may be emailed to:
[email protected]. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) An AMOC that provides an acceptable level of safety may be used for any repair, modification, or alteration required by this AD if it is approved by The Boeing Company Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO Branch, FAA, to make those findings. To be approved, the repair method, modification deviation, or alteration deviation must meet the certification basis of the airplane, and the approval must specifically refer to this AD. \n\n(l) Related Information \n\n\n\tFor more informationabout this AD, contact Christopher Baker, Aerospace Engineer, Propulsion Section, FAA, Seattle ACO Branch, 2200 South 216th St., Des Moines, WA 98198; phone and fax: 206-231- 3552; email:
[email protected]. \n\n(m) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Multi-Operator Message MOM-MOM-20-0522-01B, dated June 24, 2020. \n\t(ii) (Reserved) \n\t(3) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Contractual & Data Services (C&DS), 2600 Westminster Blvd., MC 110-SK57, Seal Beach, CA 90740- 5600; telephone 562-797-1717; internet https://www.myboeingfleet.com. \n\t(4) You may view this service information at the FAA, Airworthiness Products Section, Operational Safety Branch, 2200 South 216th St., Des Moines, WA. For information on the availability of this material at the FAA, call 206-231-3195. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, email
[email protected], or go to: https://www.archives.gov/federal-register/cfr/ibr-locations.html. \n\n\n\tIssued on July 2, 2020. Gaetano A. Sciortino, Deputy Director for Strategic Initiatives, Compliance & Airworthiness Division, Aircraft Certification Service. (FR Doc. 2020-15410 Filed 7-13-20; 2:00 pm) BILLING CODE 4910-13-P