eFlight
FAA orders · airworthiness directive · current

2017-17-13: Electrical power

FAA order 2017-17-13 is an airworthiness directive in force since October 2, 2017. The FAA's subject line: Electrical power. It names Bombardier BD-100 Challenger 300 and 350: about 889 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Bombardier Inc.
Models
BD-100-1A10 (Challenger 300)
On this site
Bombardier BD-100 Challenger 300 and 350 889 registered

Dates and paperwork

In force since
October 2, 2017
Published
August 28, 2017 (signed August 9, 2017)
Docket
FAA-2017-0481
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc., Model BD-100-1A10 airplanes. This AD was prompted by reports of low clearance in the aft equipment bay between auxiliary power unit (APU) generator power cables and a hydraulic line, which can cause damage to wire insulation. This AD requires an inspection of the APU generator power cables and the adjacent hydraulic line for damage, and repair, if necessary; and modification of the APU generator power cable installation. We are issuing this AD to address the unsafe condition on these products.

The order itself the regulatory text, as published

Show the full text (5,981 characters)
Adoption of the Amendment Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: PART 39--AIRWORTHINESS DIRECTIVES 0 1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. Sec. 39.13 [Amended] 0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): 2017-17-13 Bombardier, Inc.: Amendment 39-19003; Docket No. FAA- 2017-0481; Product Identifier 2016-NM-196-AD. (a) Effective Date This AD is effective October 2, 2017. (b) Affected ADs None. (c) Applicability This AD applies to Bombardier, Inc., Model BD-100-1A10 airplanes, certificated in any category, serial numbers 20003 through 20635 inclusive. (d) Subject Air Transport Association (ATA) of America Code 24, Electrical power. (e) Reason This AD was prompted by reports of low clearance in the aft equipment bay between auxiliary power unit (APU) generator power cables and a hydraulic line, which can cause damage to wire insulation. We are issuing this AD to prevent electrical arcing from power cables, which could cause a fire in the aft equipment bay. (f) Compliance Comply with this AD within the compliance times specified, unless already done. (g) Inspection of APU Generator Power Cables and Hydraulic Line, Repairs, and Modification Within 24 months after the effective date of this AD, do the applicable actions required by paragraph (g)(1) or (g)(2) of this AD. (1) For airplanes having serial numbers 20003 through 20500 inclusive: Do a general visual inspection of the APU generator power cables and the adjacent hydraulic line for damage, and do all applicable repairs; and modify the APU generator power cable installation; in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 100-24-28, dated July 27, 2016, except as required byparagraph (h) of this AD. Do all applicable repairs before further flight. (2) For airplanes having serial numbers 20501 through 20635 inclusive: Do a general visual inspection of the APU generator power cables and the adjacent hydraulic line for damage, and do all applicable repairs; and modify the APU generator power cable installation; in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 350-24-003, dated July 27, 2016, except as required by paragraph (h) of this AD. Do all applicable repairs before further flight. (h) Exception to the Service Information Where Bombardier Service Bulletin 100-24-28, dated July 27, 2016; and Bombardier Service Bulletin 350-24-003, dated July 27, 2016, specify to contact the manufacturer for repair, before further flight, repair using a method approved by the Manager, New York ACO Branch, FAA; or Transport Canada Civil Aviation (TCCA); or Bombardier, Inc.'s TCCA Design Approval Organization (DAO). (i) Other FAA AD Provisions The following provisions also apply to this AD: (1) Alternative Methods of Compliance (AMOCs): The Manager, New York ACO Branch, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the certification office, send it to ATTN: Program Manager, Continuing Operational Safety, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; fax 516-794-5531. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. (2) Contacting the Manufacturer: For any requirement in this AD to obtain corrective actions from a manufacturer, the action must be accomplished using a method approved by the Manager, New York ACO Branch, FAA; or TCCA; or Bombardier, Inc.'s TCCA DAO. If approved by the DAO, the approval must include the DAO-authorized signature. (j) Related Information (1) Refer to Mandatory Continuing Airworthiness Information (MCAI) Canadian Airworthiness Directive CF-2016-28, dated September 15, 2016, for related information. This MCAI may be found in the AD docket on the Internet at http://www.regulations.gov by searching for and locating Docket No. FAA-2017-0481. (2) For more information about this AD, contact Assata Dessaline, Aerospace Engineer, Avionics and Administrative Services Section, FAA, New York ACO Branch, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7301; fax 516-794-5531. (k) Material Incorporated by Reference (1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under5 U.S.C. 552(a) and 1 CFR part 51. (2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise. (i) Bombardier Service Bulletin 100-24-28, dated July 27, 2016. (ii) Bombardier Service Bulletin 350-24-003, dated July 27, 2016. (3) For service information identified in this AD, contact Bombardier, Inc., 400 C[ocirc]te-Vertu Road West, Dorval, Qu[eacute]bec H4S 1Y9, Canada; telephone 514-855-5000; fax 514-855- 7401; email [email protected]; Internet http://www.bombardier.com. (4) You may view this service information at the FAA, Transport Standards Branch, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. (5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or goto: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

Related safety bulletins advice on the same designs, not orders

2022-05-17AIR-22-02R1 · PITOT/STATIC ANTI-ICE SYSTEM
2022-02-25AIR-22-02 · PITOT/STATIC ANTI-ICE SYSTEM
2021-03-22NM-18-32R1 · Electrical Power - Direct Current Power Center
2018-12-03NM-18-32 · Electrical Power - Direct Current Power Center

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2017-17-13.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.