Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2015-19-04 The Boeing Company: Amendment 39-18267; Docket No. FAA- 2014-0126; Directorate Identifier 2013-NM-236-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective October 21, 2015. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to all The Boeing Company Model 757-200, -200PF, -200CB, and -300 series airplanes, certificated in any category. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 28, Fuel. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by reports of latently failed fuel shutoff valvesdiscovered during fuel filter replacement. We are issuing this AD to detect and correct latent failures of the fuel shutoff valve to the engine and auxiliary power unit (APU), which could result in the inability to shut off fuel to the engine and APU and, in case of certain fires, an uncontrollable fire that could lead to structural failure. \n\n((Page 55510)) \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Revision of Maintenance or Inspection Program \n\n\n\tWithin 30 days after the effective date of this AD, revise the maintenance or inspection program, as applicable, to add airworthiness limitations Nos. 28-AWL-ENG and 28-AWL-APU, by incorporating the information specified in figure 1 and figure 2 to paragraph (g) of this AD into the Airworthiness Limitations Section of the Instructions for Continued Airworthiness. The initial compliance time for accomplishing the actions specified in figure 1 and figure 2 to paragraph (g) of this AD is within 10 days after accomplishing the maintenance or inspection program revision required by this paragraph. \n\n\n\tFigure 1 to Paragraph (g) of This AD--Engine Fuel Shutoff Valve (Fuel Spar Valve) Position Indication \n\tOperational Check ---------------------------------------------------------------------------------------------------------------- \n\tAWL No. Task Interval Applicability Description ---------------------------------------------------------------------------------------------------------------- 28-AWL-ENG.................. ALI DAILY............... ALL................ Engine Fuel Shutoff \n\tINTERVAL NOTE: Not APPLICABILITY NOTE: Valve (Fuel Spar Valve) \n\trequired on days Only applies to Position Indication \n\twhen the airplane airplanes with an Operational Check. \n\tis not used in MA20A2027 Concern: The fuel spar \n\trevenue service. (S343T003-56) or valve actuator design \n\tThe check must be MA30A1001 can result in airplanes \n\tdone before further (S343T003-66) operating with a failed \n\tflight once the actuator installed fuel spar valve \n\tairplane is at the engine fuel actuator that is not \n\treturned to revenue spar valve reported. A latently \n\tservice. position. failed fuel spar valve \n\tactuator could prevent \n\tfuel shutoff to an \n\tengine. In the event of \n\tcertain engine fires, \n\tthe potential exists \n\tfor an engine fire to \n\tbe uncontrollable. \n\tPerform one of the \n\tfollowing checks/ \n\tinspection of the fuel \n\tspar valve position \n\t(unless checked by the \n\tflightcrew in a manner \n\tapproved by the \n\tprincipal operations \n\tinspector). \n\tA. Operational check \n\tduring engine shutdown \n\t1. Do an operational \n\tcheck of the left \n\tengine fuel spar valve \n\tactuator. \n\ta. As the L FUEL CONTROL \n\tswitch on the quadrantcontrol stand is moved \n\tto the CUTOFF position, \n\tverify the left SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t2. Do an operational \n\tcheck of the right \n\tengine fuel spar valve \n\tactuator. \n\ta. As the R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand is moved \n\tto the CUTOFF position, \n\tverify the right SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\tB. Operational check \n\tduring engine start \n\t1. Do an operational \n\tcheck of the left \n\tengine fuel spar valve \n\tactuator. \n\ta. As the L FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol standis moved \n\tto the RUN position, \n\tverify the left SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t2. Do an operational \n\tcheck of the right \n\tengine fuel spar valve \n\tactuator. \n\ta. As the R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand is moved \n\tto the RUN position, \n\tverify the right SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\tC. Operational check \n\twithout engine \n\toperation \n\t1. Supply electrical \n\tpower to the airplane \n\tusing standard \n\tpractices. \n\t2. Make sure all fuel \n\tpump switches on the \n\tOverhead Panel are in \n\tthe OFFposition. \n\n((Page 55511)) \n\n\n\n\n\t3. If the APU is \n\trunning, open and \n\tcollar the L FWD FUEL \n\tBOOST PUMP (C00372) \n\tcircuit breaker on the \n\tMain Power Distribution \n\tPanel. \n\t4. Make sure LEFT and \n\tRIGHT ENG FIRE switches \n\ton the Aft Aisle Stand \n\tare in the NORMAL (IN) \n\tposition. \n\t5. Make sure L and R \n\tEngine Start Selector \n\tSwitches on the \n\tOverhead Panel are in \n\tthe OFF position. \n\t6. Do an operational \n\tcheck of the left \n\tengine fuel spar valve \n\tactuator. \n\ta. Move L FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tRUN position and wait \n\tapproximately 10 \n\tseconds. \n\tNOTE: It is normal under \n\tthis test condition for \n\tthe ENG VALVE \n\tdisagreement light on \n\tthe quadrant control \n\tstand to stay \n\tilluminated. \n\tb. Move L FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tCUTOFF position. \n\tc. Verify the left SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\td. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t7. Do an operational \n\tcheck of the right \n\tengine fuel spar valve \n\tactuator. \n\ta. Move R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tRUN position and wait \n\tapproximately 10 \n\tseconds. \n\tNOTE: It is normal under \n\tthis test condition for \n\tthe ENG VALVE \n\tdisagreement light on \n\tthe quadrant control \n\tstand to stay \n\tilluminated. \n\tb. Move R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tCUTOFF position. \n\tc. Verify the right SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\td. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t8. If the L FWD FUEL \n\tBOOST PUMP circuit \n\tbreaker was collared in \n\tstep3, remove collar \n\tand close. \n\tD. Perform an inspection \n\tof the fuel spar valve \n\tactuator position \n\tNOTE: This inspection \n\tmay be most useful \n\twhenever the SPAR VALVE \n\tlight does not function \n\tproperly. \n\t1. Make sure the L FUEL \n\tCONTROL switch on the \n\tquadrant control stand \n\tis in the CUTOFF \n\tposition. \n\tNOTE: It is not \n\tnecessary to cycle the \n\tFUEL CONTROL switch to \n\tdo this inspection. \n\t2. Inspect the left \n\tengine fuel spar valve \n\tactuator located in the \n\tleft rear spar. \n\tNOTE: Access is through \n\taccess panel 551EBX. \n\ta. Verify the manual \n\toverride handle on the \n\tengine fuel spar valve \n\tactuator is in the \n\tCLOSED position. \n\tb. Repair or replace any \n\tactuator that is not in \n\tthe CLOSED position \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t3. Make sure the R FUEL \n\tCONTROL switch on the \n\tquadrant control stand \n\tis in the CUTOFF \n\tposition. \n\tNOTE: It is not \n\tnecessary to cycle the \n\tFUEL CONTROL switch to \n\tdo this inspection. \n\t4. Inspect the right \n\tengine fuel spar valve \n\tactuator located in the \n\tright rear spar. \n\tNOTE: Access is through \n\taccess panel 651EBX. \n\ta. Verify the manual \n\toverride handle on the \n\tengine fuel spar valve \n\tactuator is in the \n\tCLOSED position. \n\tb. Repair or replace any \n\tactuator that is not in \n\tthe CLOSED position \n\t(refer to Boeing AMM 28- \n\t22-11). ---------------------------------------------------------------------------------------------------------------- \n\n\n\n((Page 55512)) \n\n\n\n\n\tFigure 2 to Paragraph (g) of This AD--Auxiliary Power Unit (APU) Fuel Shutoff Valve Position Indication \n\tOperational Check ---------------------------------------------------------------------------------------------------------------- \n\tAWL No. Task Interval Applicability Description ---------------------------------------------------------------------------------------------------------------- 28-AWL-APU.................. ALI 10 DAYS............. ALL................ APU Fuel Shutoff Valve \n\tPosition Indication \n\tOperational Check. \n\t............. INTERVAL NOTE: Not APPLICABILITY NOTE: Concern: The APU fuel \n\trequired on days Only applies to shutoff valve actuator \n\twhen the airplane airplanes with an design can result in \n\tis not used in MA20A2027 airplanes operating \n\trevenue service. (S343T003-56) or with a failed APU fuel \n\tMust be done before MA30A1001 shutoff valve actuator \n\tfurther flight with (S343T003-66) that is not reported. A \n\tan operational APU actuator installed latently failed APU \n\tif it has been 10 at the APU fuel fuel shutoff valve \n\tor more calendar shutoff valve actuator could prevent \n\tdays since last position. fuel shutoff to the \n\tcheck.. APU. In the event of \n\tcertain APU fires, thepotential exists for an \n\tAPU fire to be \n\tuncontrollable. \n\tPerform the operational \n\tcheck of the APU fuel \n\tshutoff valve position \n\tindication (unless \n\tchecked by the \n\tflightcrew in a manner \n\tapproved by the \n\tprincipal operations \n\tinspector). \n\tA. Do an operational \n\tcheck of the APU fuel \n\tshutoff valve position \n\tindication. \n\t1. If the APU is \n\trunning, unload and \n\tshut down the APU using \n\tstandard practices. \n\t2. Supply electrical \n\tpower to the airplane \n\tusing standard \n\tpractices. \n\t3. Make sure the APU \n\tFIRE switch on the Aft \n\tAisle Stand is in the \n\tNORMAL (IN) position. \n\t4. Make sure there is at \n\tleast 700 lbs (300 kgs) \n\tof fuel in the Left \n\tMain Tank. \n\t5. Move APU Selector \n\tswitch on the Overhead \n\tPanel to the ON \n\tposition and wait \n\tapproximately 10 \n\tseconds. \n\t6. Move APU Selector \n\tswitch on the Overhead \n\tPanel to the OFF \n\tposition. \n\t7. Verify the APU FAULT \n\tlight on the Overhead \n\tPanel illuminatesand \n\tthen goes off. \n\t8. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight \n\trequiring APU \n\tavailability, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t25-11). \n\tNOTE: Dispatch may be \n\tpermitted per MMEL 28- \n\t25-2 if APU is not \n\trequired for flight. ---------------------------------------------------------------------------------------------------------------- \n\n(h) No Alternative Actions or Intervals \n\n\n\tAfter accomplishment of the maintenance or inspection program revision required by paragraph (g) of this AD, no alternative actions (e.g., inspections) or intervals may be used unless the actions or intervals are approved as an alternative method of compliance (AMOC) in accordance with the procedures specified in paragraph (i)(1) of this AD. \n\n(i) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO) FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (j) of this AD. Information may be emailed to:
[email protected]. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\n(j) Related Information \n\n\n\tFor more information about this AD, contact Rebel Nichols, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6509; fax: 425-917-6590; email:
[email protected]. \n\n(k) Material Incorporated by Reference \n\n\n\tNone.