Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n\n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2015-19-02 The Boeing Company: Amendment 39-18265; Docket No. FAA- 2014-0127; Directorate Identifier 2013-NM-237-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective October 21, 2015. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to all The Boeing Company Model 767-200, -300, - 300F, and -400ER series airplanes, certificated in any category. \n\n(d) Subject \n\n\n\tJoint Aircraft System Component (JASC) Code 28, Fuel. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by reports of latently failed fuel shutoff valves discovered during fuel filter replacement. We are issuing this AD to detect and correct latent failures of the fuel shutoff valve to the engine and auxiliary power unit (APU), which could result in the inability to shut off fuel to the engine and APU and, in case of certain fires, an uncontrollable fire that could lead to structural failure. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Revision of Maintenance or Inspection Program \n\n\n\tWithin 30 days after the effective date of this AD, revise the maintenance or inspection program, as applicable, to add airworthiness limitation numbers 28-AWL-ENG, 28-AWL-MOV, and 28-AWL- APU, by incorporating the information specified in Figure 1, Figure 2, and Figure 3 to paragraph (g) of this AD into the Airworthiness Limitations Section of the Instructions for Continued Airworthiness. The initial compliance time for accomplishing the actions specified in Figure 1, Figure 2, and Figure 3 to paragraph (g) of this AD is within 10 days after accomplishing the maintenance or inspection program revision required by this paragraph. \n\n\n\tFigure 1 to Paragraph (g) of This AD--Engine Fuel Shutoff Valve (Fuel Spar Valve) Position Indication \n\tOperational Check ---------------------------------------------------------------------------------------------------------------- \n\tAWL No. Task Interval Applicability Description ---------------------------------------------------------------------------------------------------------------- 28-AWL-ENG.................. ALI DAILY............... 767-200, -300, and - Engine Fuel Shutoff \n\tINTERVAL NOTE: The 300F airplanes. Valve (Fuel Spar Valve) \n\toperational check APPLICABILITY NOTE: Position Indication \n\tis not required on Applies to Operational Check. \n\tdays when the airplanes with an Concern: The fuel spar \n\tairplane is notactuator installed valve actuator design \n\tused in revenue at the engine fuel can result in airplanes \n\tservice.. spar valve operating with a failed \n\tThe check must be position having fuel spar valve \n\tdone before further part number (P/N) actuator that is not \n\tflight once the MA20A2027 reported. A latently \n\tairplane is (S343T003-56) or P/ failed fuel spar valve \n\treturned to revenue N MA30A1001 actuator could prevent \n\tservice. (S343T003-66).. fuel shutoff to an \n\tengine. In the event of \n\tcertain engine fires, \n\tthe potential exists \n\tfor an engine fire to \n\tbe uncontrollable. \n\tPerform one of the \n\tfollowing checks/ \n\tinspection of the fuel \n\tspar valve position \n\t(unless checked by the \n\tflightcrew in a manner \n\tapproved by the \n\tprincipal operations \n\tinspector): \n\tA. Operational Check \n\tduring engine shutdown. \n\t1. Do an operational \n\tcheck of the left \n\tengine fuel spar valve \n\tactuator. \n\ta. As the L FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand is moved \n\tto the CUTOFF position, \n\tverify the left SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing \n\tairplane maintenance \n\tmanual (AMM) 28-22-11). \n\t2. Do an operational \n\tcheck of the right \n\tengine fuel spar valve \n\tactuator. \n\ta. As the R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand is moved \n\tto the CUTOFF position, \n\tverify the right SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\tB. Operational check \n\tduring engine start. \n\t1. Do an operational \n\tcheck of the left \n\tengine fuel spar valve \n\tactuator. \n\n((Page 55519)) \n\n\n\n\n\ta. As the L FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand is moved \n\tto the RUN (or RICH) \n\tposition, verify the \n\tleft SPAR VALVE \n\tdisagreement light on \n\tthe quadrant control \n\tstand illuminates and \n\tthen goes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t2. Do an operational \n\tcheck of the right \n\tengine fuel spar valve \n\tactuator. \n\ta. As the R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand is moved \n\tto the RUN (or RICH) \n\tposition, verify the \n\tright SPAR VALVE \n\tdisagreement light on \n\tthe quadrant control \n\tstand illuminates and \n\tthen goes off. \n\tb. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\tC. Operational check \n\twithout engine \n\toperation. \n\t1. Supply electrical \n\tpower to the airplane \n\tusing standard \n\tpractices. \n\t2. Make sure all fuel \n\tpump switches on the \n\tOverhead Panel are in \n\tthe OFF position. \n\t3. If the auxiliary \n\tpower unit (APU) is \n\trunning, open and \n\tcollar the L FWD FUEL \n\tBOOST PUMP (C00372) \n\tcircuit breaker on the \n\tMain Power Distribution \n\tPanel. \n\t4. Make sure LEFT and \n\tRIGHT ENG FIRE switches \n\ton the Aft Aisle Stand \n\tare in the NORMAL (IN) \n\tposition. \n\t5. Make sure L and R ENG \n\tSTART Selector Switches \n\ton the Overhead Panel, \n\tare in the OFF \n\tposition. \n\t6. Do an operational \n\tcheck of the left \n\tengine fuel spar valve \n\tactuator. \n\ta. Move L FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tRUN position and wait \n\tapproximately 10 \n\tseconds. \n\tNOTE: It is normal under \n\tthis test condition for \n\tthe ENG VALVE \n\tdisagreement light on \n\tthe quadrant control \n\tstand to stay \n\tilluminated. \n\tb. Move L FUEL CONTROLswitch on the quadrant \n\tcontrol stand to the \n\tCUTOFF position. \n\tc. Verify the left SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\td. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t7. Do an operational \n\tcheck of the right \n\tengine fuel spar valve \n\tactuator. \n\ta. Move R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tRUN position and wait \n\tapproximately 10 \n\tseconds once the FUEL \n\tCONTROL switch is in \n\tthe RUN position or the \n\tAPU selector switch on \n\tthe overhead panel is \n\tin the ON position. \n\tNOTE: It is normal under \n\tthis test condition for \n\tthe ENG VALVE \n\tdisagreement light on \n\tthe quadrant control \n\tstand to stay \n\tilluminated. \n\tb. Move R FUEL CONTROL \n\tswitch on the quadrant \n\tcontrol stand to the \n\tCUTOFF position. \n\tc. Verify the right SPAR \n\tVALVE disagreement \n\tlight on the quadrant \n\tcontrol stand \n\tilluminates and then \n\tgoes off. \n\td. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t8. If the L FWD FUEL \n\tBOOST PUMP circuit \n\tbreaker was collared in \n\tstep 3, remove collar \n\tand close. \n\tD. Perform an inspection \n\tof the fuel spar valve \n\tactuator position. \n\n((Page 55520)) \n\n\n\n\n\tNOTE: This inspection \n\tmay be most useful \n\twhenever the SPAR VALVE \n\tlight does not function \n\tproperly. \n\t1. Make sure the L FUEL \n\tCONTROL switch on the \n\tquadrant control stand \n\tis in the CUTOFF \n\tposition. \n\tNOTE: It is not \n\tnecessary to cycle the \n\tFUEL CONTROL switch to \n\tdo this inspection. \n\t2. Inspect the left \n\tengine fuel spar valve \n\tactuator located in the \n\tleft rear spar. \n\tNOTE: The Fuel Spar \n\tValve actuators are \n\tlocated behind main \n\tgear doors on the rear \n\tspar. \n\ta. Verify the manual \n\toverride handle on the \n\tengine fuel spar valve \n\tactuator is in the \n\tCLOSED position. \n\tb. Repair or replace any \n\tfuel spar valve \n\tactuator that is not in \n\tthe CLOSED position \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t3. Make sure the R FUEL \n\tCONTROL switch on the \n\tquadrant control stand \n\tis in the CUTOFF \n\tposition. \n\tNOTE: It is not \n\tnecessary to cycle the \n\tFUEL CONTROL switch to \n\tdo this inspection. \n\t4. Inspect the right \n\tengine fuel spar valve \n\tactuator located in the \n\tright rear spar. \n\tNOTE: The Fuel Spar \n\tValve actuators are \n\tlocated behind main \n\tgear doors on the rear \n\tspar. \n\ta. Verify the manual \n\toverride handle on the \n\tengine fuel spar valve \n\tactuator is in the \n\tCLOSED position. \n\tb. Repair or replace any \n\tfuel spar valve \n\tactuator that is not in \n\tthe CLOSED position \n\t(refer to Boeing AMM 28- \n\t22-11). ----------------------------------------------------------------------------------------------------------------Figure 2 to Paragraph (g) of This AD--Engine Fuel Shutoff Valve (Fuel Spar Valve) Actuator Inspection ---------------------------------------------------------------------------------------------------------------- \n\tAWL No. Task Interval Applicability Description ---------------------------------------------------------------------------------------------------------------- 28-AWL-MOV.................. ALI 10 DAYS............. 767-400ER series Engine Fuel Shutoff \n\tINTERVAL NOTE: The airplanes. Valve (Fuel Spar Valve) \n\tinspection is not APPLICABILITY NOTE: Actuator Inspection \n\trequired on days Applies to Concern: The fuel spar \n\twhen the airplane airplanes with an valve actuator design \n\tis not used in actuator installed can result in airplanes \n\trevenue service. at the engine fuel operating with a failed \n\tThe inspection must spar valvefuel spar valve \n\tbe done before position having actuator that is not \n\tfurther flight if part number (P/N) reported. A latently \n\tit has been 10 or MA20A2027 failed fuel spar valve \n\tmore calendar days (S343T003-56) or P/ actuator would prevent \n\tsince last N MA30A1001 fuel shutoff to an \n\tinspection.. (S343T003-66).. engine. In the event of \n\tcertain engine fires, \n\tthe potential exists \n\tfor an engine fire to \n\tbe uncontrollable. \n\tPerform an inspection of \n\tthe fuel spar valve \n\tactuator position. \n\tNOTE: The fuel spar \n\tvalve actuators are \n\tlocated behind main \n\tgear doors on the rear \n\tspar. \n\t1. Make sure the L FUEL \n\tCONTROL switch on the \n\tquadrant control stand \n\tis in the CUTOFF \n\tposition. \n\tNOTE: It is not \n\tnecessary to cycle the \n\tFUEL CONTROL switch to \n\tdo this inspection. \n\t2. Inspect the left \n\tengine fuel spar valve \n\tactuator located in the \n\tleft rear spar.a. Verify the manual \n\toverride handle on the \n\tengine fuel spar valve \n\tactuator is in the \n\tCLOSED position. \n\tb. Repair or replace any \n\tfuel spar valve \n\tactuator that is not in \n\tthe CLOSED position \n\t(refer to Boeing AMM 28- \n\t22-11). \n\t3. Make sure the R FUEL \n\tCONTROL switch on the \n\tquadrant control stand \n\tis in the CUTOFF \n\tposition. \n\tNOTE: It is not \n\tnecessary to cycle the \n\tFUEL CONTROL switch to \n\tdo this inspection. \n\t4. Inspect the right \n\tengine fuel spar valve \n\tactuator located in the \n\tright rear spar. \n\ta. Verify the manual \n\toverride handle on the \n\tengine fuel spar valve \n\tactuator is in the \n\tCLOSED position. \n\tb. Repair or replace any \n\tfuel spar valve \n\tactuator that is not in \n\tthe CLOSED position \n\t(refer to Boeing AMM 28- \n\t22-11). ---------------------------------------------------------------------------------------------------------------- \n\n\n\n((Page 55521)) \n\n\n\n\n\tFigure 3 to Paragraph (g) of This AD--Auxiliary Power Unit (APU) Fuel Shutoff Valve Position Indication \n\tOperational Check ---------------------------------------------------------------------------------------------------------------- \n\tAWL No. Task Interval Applicability Description ---------------------------------------------------------------------------------------------------------------- 28-AWL-APU.................. ALI 10 DAYS............. ALL................ APU Fuel Shutoff Valve \n\tINTERVAL NOTE: The APPLICABILITY NOTE: Position Indication \n\toperational check Applies to Operational Check \n\tis not required on airplanes with an Concern: The APU fuel \n\tdays when the actuator installed shutoff valve actuator \n\tairplane is not at the APU fuel design can result in \n\tused in revenue shutoff valve airplanes operating \n\tservice. The position having with a failed APU fuel \n\toperational check part number (P/N) shutoff valve actuator \n\tmust be done before MA20A2027 that is not reported. A \n\tfurther flight with (S343T003-56) or latently failed APU \n\tan operational APU MA30A1001 fuel shutoff valve \n\tif it has been 10 (S343T003-66).. actuator could prevent \n\tor more calendar fuel shutoff to the \n\tdays since last APU. In the event of \n\tcheck.. certain APU fires, the \n\tpotential exists for an \n\tAPU fire to be \n\tuncontrollable. \n\tPerform the operational \n\tcheck of the APU fuel \n\tshutoff valve position \n\tindication (unless \n\tchecked by the \n\tflightcrew in a manner \n\tapproved by the \n\tprincipal operations \n\tinspector). \n\tA. Do an operational \n\tcheck of the APU fuel \n\tshutoff valve position \n\tindication. \n\t1. If the APU is \n\trunning, unload and \n\tshut down the APU using \n\tstandard practices. \n\t2. Supply electricalpower to the airplane \n\tusing standard \n\tpractices. \n\t3. Make sure the APU \n\tFIRE switch on the Aft \n\tAisle Stand is in the \n\tNORMAL (IN) position. \n\t4. Make sure there is at \n\tleast 1,000 lbs (500 \n\tkgs) of fuel in the \n\tLeft Main Tank. \n\t5. Move APU Selector \n\tswitch on the Overhead \n\tPanel to the ON \n\tposition and wait \n\tapproximately 10 \n\tseconds once the FUEL \n\tCONTROL switch is in \n\tthe RUN position or the \n\tAPU selector switch on \n\tthe overhead panel is \n\tin the ON position. \n\t6. Move the APU Selector \n\tswitch on the Overhead \n\tPanel to the OFF \n\tposition. \n\t7. Verify the APU FAULT \n\tlight on the Overhead \n\tPanel illuminates and \n\tthen goes off. \n\t8. If the test fails \n\t(light fails to \n\tilluminate), before \n\tfurther flight \n\trequiring APU \n\tavailability, repair \n\tfaults as required \n\t(refer to Boeing AMM 28- \n\t25-02). \n\tNOTE: Dispatch may be \n\tpermitted per MMEL 28- \n\t25-02 if APU is not \n\trequired for flight. ---------------------------------------------------------------------------------------------------------------- \n\n(h) No Alternative Actions or Intervals \n\n\n\tAfter accomplishment of the maintenance or inspection program revision required by paragraph (g) of this AD, no alternative actions (e.g., inspections) or intervals may be used unless the actions or intervals are approved as an alternative method of compliance (AMOC) in accordance with the procedures specified in paragraph (i)(1) of this AD. \n\n(i) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO) FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (j) of this AD. Information may be emailed to:
[email protected]. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\n(j) Related Information \n\n\n\tFor more information about this AD, contact Rebel Nichols, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6509; fax: 425-917-6590; email:
[email protected]. \n\n(k) Material Incorporated by Reference \n\n\n\tNone.