Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\nSec. 39.13 (Amended) \n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2015-17-13 The Boeing Company: Amendment 39-18246 ; Docket No. FAA- 2014-0523; Directorate Identifier 2014-NM-050-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective October 7, 2015. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to The Boeing Company Model 777-200 and -300 series airplanes, certificated in any category, equipped with Pratt & Whitney engines, as identified in Boeing Special Attention Service Bulletin 777-54-0027, Revision 1, dated September 12, 2013. \n\n((Page 52952)) \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 54, Nacelles/ pylons. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by reports of blocked drain lines at the engine forward strut that caused flammable fluid to accumulate in a flammable leakage zone. We are proposing this AD to detect and correct blockage of forward strut drain lines, which could cause flammable fluids to collect in the forward strut area and potentially cause an uncontrolled fire or cause failure of engine attachment structure and consequent airplane loss. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Functional Check, Cleaning, and Corrective Actions \n\n\n\tAt the applicable times specified in paragraph 1.E., ''Compliance,'' of Boeing Special Attention Service Bulletin 777-54- 0027, Revision 1, dated September 12, 2013, except as provided by paragraph (h) of this AD, do the actions specified in paragraphs (g)(1) and (g)(2) of this AD, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-54-0027, Revision 1, dated September 12, 2013. Repeat the functional check required by paragraph (g)(1) of this AD, thereafter at the applicable times specified in paragraph 1.E., ''Compliance,'' of Boeing Special Attention Service Bulletin 777-54-0027, Revision 1, dated September 12, 2013, until the terminating action specified in paragraph (i) of this AD is done. \n\t(1) Do a functional check for blockage of the forward strut drain line of the left and right strut and do all applicable corrective actions (including cleaning or replacing blocked drain tubes, repairing fluid leaks, and cleaning the inlet drain screen on the right system disconnect assembly inlet). Do all applicable corrective actions before further flight. Alternate tee fitting part numbers BACT16BR120612JN and AS4139J120612 may be used during the replacement of the forward strut drain lines, provided the installation is performed in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-54-0027, Revision 1, dated September 12, 2013. \n\t(2) Do a one-time cleaning of the smaller forward strut drain lines connected to the left systems disconnect, the strut forward lower spar, and the forward fire seal pan inlets. \n\n(h) Exception to the Service Information Specifications \n\n\n\tWhere Boeing Special Attention Service Bulletin 777-54-0027, Revision 1, dated September 12, 2013, refers to a compliance time ''after the Revision 1 date of this Service Bulletin,'' this AD requires compliance within the specified compliance time after the effective date of this AD. \n\n(i) Optional Terminating Action \n\n\n\tAccomplishment of the actions specified in paragraphs (i)(1) through (i)(4) of this AD, for both the left and right struts, in accordance with the Accomplishment Instructions of Boeing Special Attention Service Bulletin 777-71-0055, Revision 1, dated April 15, 2015, and accomplishment of the revision specified in paragraph (i)(5) of this AD, terminates the repetitive functional checks required by paragraph (g)(1) of this AD at the modified area only. \n\t(1) Disconnect and remove the forward strut drain lines. \n\t(2) Clean the left systems disconnect, the strut forward lower spar, and the forward fireseal pan drain lines. \n\t(3) Install new forward strut drain lines and insulation blankets. \n\t(4) Do a leak check of the forward strut drain lines, for any leak, and repair if any leaking is found. \n\t(5) Revise the maintenance or inspection program, as applicable, to incorporate Airworthiness Limitation 54-AWL-01, ''Forward Strut Drain Line'', Section D.4, Pratt and Whitney Forward Strut Drain Line, of the Boeing 777 Maintenance Planning Data (MPD) Document Section 9, Airworthiness Limitations (AWLs) and Certification Maintenance Requirements (CMRs), D622W001-9, Revision October 2014. The initial compliance time for Airworthiness Limitation 54-AWL-01 is within 2,000 flight cycles or 1,500 days, whichever occurs first, after doing the actions specified in paragraphs (i)(1) through (i)(4) of this AD. \n\n(j) No Alternative Actions or Intervals \n\n\n\tAfter accomplishing the revision required by paragraph (i)(5) of this AD, no alternative actions (e.g., inspections) or intervals may be used unless the actions or intervals are approved as an alternative method of compliance (AMOC) in accordance with the procedures specified in paragraph (l) of this AD. \n\n(k) Credit for Previous Actions \n\n\n\tThis paragraph provides credit for actions required by paragraph (i) of this AD, if those actions were performed before the effective date of this AD using Boeing Special Attention Service Bulletin 777-71- 0055, dated June 12, 2014, which is not incorporated by reference in this AD. \n\n(l) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested usingthe procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (m)(1) of this AD. Information may be emailed to:
[email protected]. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) An AMOC that provides an acceptable level of safety may be used for any repair required by this AD if it is approved by the Boeing Commercial Airplanes Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO, to make those findings. For a repair method to be approved, the repair must meet the certification basis of the airplane, and the approval must specifically refer to this AD. \n\n(m) Related Information \n\n\n\t(1) For more information about this AD, contact Kevin Nguyen, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; phone: 425-917-6501; fax: 425-917-6590; email:
[email protected]. \n\t(2) Service information identified in this AD that is not incorporated by reference is available at the addresses specified in paragraphs (n)(3) and (n)(4) of this AD. \n\n(n) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the \n\n((Page 52953)) \n\nactions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Special Attention Service Bulletin 777-54-0027, Revision 1, dated September 12, 2013. \n\t(ii) Boeing Special Attention Service Bulletin 777-71-0055, Revision 1, dated April 15, 2015. \n\t(iii) Airworthiness Limitation 54-AWL-01, ''Forward Strut Drain Line'', Section D.4, Pratt and Whitney Forward Strut Drain Line, of the Boeing 777 Maintenance Planning Data (MPD) Document Section 9, Airworthiness Limitations (AWLs) and Certification Maintenance Requirements (CMRs), D622W001-9, Revision October 2014. \n\t(3) For service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P. O. Box 3707, MC 2H-65, Seattle, WA 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. \n\t(4) You may view this service information at FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. \n\t(5) You may view this service information that is incorporated by reference at the National Archives andRecords Administration (NARA). For information on the availability of this material at NARA, call 202- 741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.