Adoption of the Amendment \n\n\n\tAccordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: \n\nPART 39--AIRWORTHINESS DIRECTIVES \n\n0 1. The authority citation for part 39 continues to read as follows: \n\n\n\tAuthority: 49 U.S.C. 106(g), 40113, 44701. \n\n((Page 27077)) \n\nSec. 39.13 (Amended) \n\n\n\n0 2. The FAA amends Sec. 39.13 by adding the following new airworthiness directive (AD): \n\n2015-09-05 The Boeing Company: Amendment 39-18151; Docket No. FAA- 2014-0429; Directorate Identifier 2014-NM-039-AD. \n\n(a) Effective Date \n\n\n\tThis AD is effective June 16, 2015. \n\n(b) Affected ADs \n\n\n\tNone. \n\n(c) Applicability \n\n\n\tThis AD applies to The Boeing Company Model 747-400 and 747-400F airplanes, certificated in any category, as identified in Boeing Alert Service Bulletin 747-25A3640, dated January 8, 2014. \n\n(d) Subject \n\n\n\tAir Transport Association (ATA) of America Code 25, Equipment/ Furnishings. \n\n(e) Unsafe Condition \n\n\n\tThis AD was prompted by reports of cracking in the main equipment center (MEC) drip shield and exhaust plenum. We are issuing this AD to prevent water penetration into the MEC, which could result in an electrical short and potential loss of several functions essential for safe flight. \n\n(f) Compliance \n\n\n\tComply with this AD within the compliance times specified, unless already done. \n\n(g) Installation \n\n\n\tWithin 24 months after the effective date of this AD, install a fiberglass reinforcing overcoat on the MEC drip shield, in accordance with the Accomplishment Instructions of Boeing Alert Service Bulletin 747-25A3640, dated January 8, 2014. \n\n(h) Alternative Methods of Compliance (AMOCs) \n\n\n\t(1) The Manager, Seattle Aircraft Certification Office (ACO), FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or localFlight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (i) of this AD. Information may be emailed to:
[email protected]. \n\t(2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. \n\t(3) An AMOC that provides an acceptable level of safety may be used for any repair required by this AD if it is approved by the Boeing Commercial Airplanes Organization Designation Authorization (ODA) that has been authorized by the Manager, Seattle ACO, to make those findings. For a repair method to be approved, the repair must meet the certification basis of the airplane, and the approval must specifically refer to this AD. \n\t(4) If any service information contains steps that are identified as RC (Required for Compliance), those steps must be done to comply with this AD; any steps that are not labeled as RC are recommended. Those steps that are not labeled as RC may be deviated from using accepted methods in accordance with the operator's maintenance or inspection program without obtaining approval of an AMOC, provided the steps labeled as RC can be done and the airplane can be put back in a serviceable condition. Any substitutions or changes to steps labeled as RC require approval of an AMOC. \n\n(i) Related Information \n\n\n\tFor more information about this AD, contact Francis Smith, Aerospace Engineer, Cabin Safety and Environmental Systems Branch, ANM-150S, FAA, Seattle Aircraft Certification Office, 1601 Lind Avenue SW., Renton, WA 98057-3356; telephone: 425-917-6596; fax: 425-917-6590; email:
[email protected]. \n\n(j) Material Incorporated by Reference \n\n\n\t(1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in thisparagraph under 5 U.S.C. 552(a) and 1 CFR part 51. \n\t(2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. \n\t(i) Boeing Alert Service Bulletin 747-25A3640, dated January 8, 2014. \n\t(ii) Reserved. \n\t(3) For Boeing service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services Management, P.O. Box 3707, MC 2H-65, Seattle, WA 98124-2207; telephone 206-544-5000, extension 1; fax 206-766-5680; Internet https://www.myboeingfleet.com. \n\t(4) You may view this referenced service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. \n\t(5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or goto: http://www.archives.gov/federal-register/cfr/ibr-locations.html.