eFlight
FAA orders · airworthiness directive · current

2014-05-23: Electrical power

FAA order 2014-05-23 is an airworthiness directive in force since April 15, 2014. The FAA's subject line: Electrical power. It names Bombardier BD-100 Challenger 300 and 350: about 889 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Bombardier Inc.
Models
BD-100-1A10 (Challenger 300)
On this site
Bombardier BD-100 Challenger 300 and 350 889 registered

Dates and paperwork

In force since
April 15, 2014
Published
March 11, 2014 (signed February 26, 2014)
Docket
FAA-2013-0798
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

We are adopting a new airworthiness directive (AD) for certain Bombardier, Inc. Model BD-100-1A10 (Challenger 300) airplanes. This AD was prompted by multiple reports of erratic electrical status indications on the push button annunciators and the engine instrument and crew alerting system. Certain of those reported incidents resulted in the airplane experiencing a momentary loss of electrical power and loss of flight displays. This AD requires modification of the direct current power centers. We are issuing this AD to prevent loss of electrical power, which could result in the loss of flight displays and reduced controllability of the airplane.

The order itself the regulatory text, as published

Show the full text (5,254 characters)
Adoption of the Amendment Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: PART 39--AIRWORTHINESS DIRECTIVES 0 1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. Sec. 39.13 [Amended] 0 2. The FAA amends Sec. 39.13 by adding the following new AD: 2014-05-23 Bombardier, Inc.: Amendment 39-17796. Docket No. FAA- 2013-0798; Directorate Identifier 2013-NM-087-AD. (a) Effective Date This airworthiness directive (AD) becomes effective April 15, 2014. (b) Affected ADs None. (c) Applicability This AD applies to Bombardier, Inc. Model BD-100-1A10 (Challenger 300) airplanes, certificated in any category, serial numbers 20003 and subsequent. (d) Subject Air Transport Association (ATA) of America Code 24, Electrical power. (e) Reason This AD was prompted by multiple reports of erratic electrical status indications on the push button annunciators and the engine instrument and crew alerting system. Certain of those reported incidents resulted in the airplane experiencing a momentary loss of electrical power and loss of flight displays. We are issuing this AD to prevent loss of electrical power, which could result in the loss of flight displays and reduced controllability of the airplane. (f) Compliance You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. (g) Direct Current Power Centers (DCPC) Modification For airplanes having serial numbers 20003 through 20405 inclusive: Within 800 flight hours after the effective date of this AD or within 24 months after the effective date of this AD, whichever occurs first, modify the left-hand DCPC, right-hand DCPC, and auxiliary DCPC, in accordance with the Accomplishment Instructions of Bombardier Service Bulletin 100-24-23, dated November 26, 2012. (h) Parts Installation Limitation As of the effective date of this AD, no person may install a DCPC having a part number specified in paragraphs (h)(1) through (h)(9) of this AD on any airplane, unless the DCPC serial number has a suffix ``R'' beside the serial number. (1) 970GC02Y04. (2) 970GC02Y05. (3) 970GC02Y06. (4) 975GC02Y04. (5) 975GC02Y05. (6) 975GC02Y06. (7) 320GC03Y04. (8) 320GC03Y05. (9) 320GC03Y06. (i) Other FAA AD Provisions The following provisions also apply to this AD: (1) Alternative Methods of Compliance (AMOCs): The Manager, New York Aircraft Certification Office (ACO), ANE-170, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the ACO, send it to ATTN: Program Manager, Continuing Operational Safety, FAA, New York ACO, 1600 Stewart Avenue, Suite 410, Westbury, NY 11590; telephone 516-228-7300; fax 516-794-5531. Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. The AMOC approval letter must specifically reference this AD. (2) Airworthy Product: For any requirement in this AD to obtain corrective actions from a manufacturer or other source, use these actions if they are FAA-approved. Corrective actions are considered FAA-approved if they are approved by the State of Design Authority (or their delegated agent). You are required to assure the product is airworthy before it is returned to service. (j) Related Information Refer to Mandatory Continuing Airworthiness Information (MCAI) Canadian Airworthiness Directive CF-2013-05, dated February 22, 2013, for related information. ThisMCAI may be found in the AD docket on the Internet at http://www.regulations.gov/#!documentDetail;D=FAA-2013-0798-0001. (k) Material Incorporated by Reference (1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. (2) You must use this service information as applicable to do the actions required by this AD, unless this AD specifies otherwise. (i) Bombardier Service Bulletin 100-24-23, dated November 26, 2012. (ii) Reserved. (3) For service information identified in this AD, contact Bombardier, Inc., 400 C[ocirc]te-Vertu Road West, Dorval, Qu[eacute]bec H4S 1Y9, Canada; telephone 514-855-5000; fax 514-855- 7401; email [email protected]; Internet http://www.bombardier.com. (4) You may view this service information at the FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability ofthis material at the FAA, call 425-227-1221. (5) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

Related safety bulletins advice on the same designs, not orders

2022-05-17AIR-22-02R1 · PITOT/STATIC ANTI-ICE SYSTEM
2022-02-25AIR-22-02 · PITOT/STATIC ANTI-ICE SYSTEM
2021-03-22NM-18-32R1 · Electrical Power - Direct Current Power Center
2018-12-03NM-18-32 · Electrical Power - Direct Current Power Center

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2014-05-23.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.