The U.S. aircraft register, updated daily
FAA orders · airworthiness directive · current

2013-24-04: Fuel

FAA order 2013-24-04 is an airworthiness directive in force since March 14, 2014. The FAA's subject line: Fuel. It names Learjet 60: about 239 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: other and general.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Learjet Inc.
Models
60
On this site
Learjet 60 239 registered

Dates and paperwork

In force since
March 14, 2014
Published
February 7, 2014 (signed December 27, 2013)
Docket
FAA-2013-0691
Replaces
2003-19-11
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

We are superseding Airworthiness Directive (AD) 2003-19-11 for certain Learjet Inc. Model 60 airplanes. AD 2003-19-11 required determining if a certain fuel crossflow tube is installed; and follow- on/corrective actions, as applicable. This new AD requires retaining all actions in AD 2003-19-11, and it also requires determining if a certain fuel crossflow tube is installed, performing repetitive measurements of the fuel crossflow tube and surrounding valves and cables, and doing corrective actions if necessary. In addition, this new AD expands the applicability of AD 2003-19-11. This AD was prompted by a report that airplanes produced since 2003 might also be subject to the unsafe condition; and that the minimum allowable clearance is not established in the airplane maintenance information. We are issuing this AD to prevent chafing and consequent failure of the fuel crossflow tube due to inadequate clearance between the tube and the flight control cables, which could result inloss of fuel from one fuel tank during normal operating conditions or loss of fuel from both main fuel tanks during fuel cross-feeding operations.

The order itself the regulatory text, as published

Show the full text (13,637 characters)
Adoption of the Amendment Accordingly, under the authority delegated to me by the Administrator, the FAA amends 14 CFR part 39 as follows: PART 39--AIRWORTHINESS DIRECTIVES 0 1. The authority citation for part 39 continues to read as follows: Authority: 49 U.S.C. 106(g), 40113, 44701. Sec. 39.13 [Amended] 0 2. The FAA amends Sec. 39.13 by removing Airworthiness Directive (AD) 2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003), and adding the following new AD: 2013-24-04 Learjet Inc.: Amendment 39-17678; Docket No. FAA-2013- 0691; Directorate Identifier 2012-NM-170-AD. (a) Effective Date This AD is effective March 14, 2014. (b) Affected ADs This AD supersedes AD 2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003). (c) Applicability This AD applies to Learjet Inc. Model 60 airplanes, certificated in any category, serial numbers 60-001 through 60-409 inclusive. (d) Subject AirTransport Association (ATA) of America Code 28, Fuel. (e) Unsafe Condition This AD was prompted by a report that airplanes produced since 2003 might also be subject to the unsafe condition; and that the minimum allowable clearance is not established in the airplane maintenance information. We are issuing this AD to prevent chafing and consequent failure of the fuel crossflow tube due to inadequate clearance between the tube and the flight control cables, which could result in loss of fuel from one fuel tank during normal operating conditions or loss of fuel from both main fuel tanks during fuel cross-feeding operations. (f) Compliance Comply with this AD within the compliance times specified, unless already done. (g) Retained Part Identification for Airplanes Having Serial Numbers 60-001 Through 60-145 Inclusive This paragraph restates the part identification required by paragraph (a) of AD 2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003). For airplanes having serial numbers 60-001 through 60-145 inclusive: Within 25 flight hours after November 3, 2003 (the effective date of AD 2003-19-11), inspect the fuel crossflow tube to determine whether part number (P/N) 6026020-005 is installed. Instead of inspecting the tube, a review of airplane maintenance records is acceptable if the part number of the tube can be positively determined from that review. (h) Retained Clearance Measurement and Corrective Action for Airplanes Having Serial Numbers 60-001 Through 60-145 Inclusive, With Revised Repair Language This paragraph restates the clearance measurement and corrective action required by paragraph (b) of AD 2003-19-11, Amendment 39- 13314 (68 FR 55812, September 29, 2003), with revised repair language. For airplanes having serial numbers 60-001 through 60-145 inclusive: If P/N 6026020-005 is found installed during the review or inspection required by paragraph (g) of this AD, before further flight, measure the clearance between the fuel crossflow tube and the flight control cables to determine if it is at least 0.35 inch, per paragraph 2.B.(8) of the Accomplishment Instructions of Bombardier Alert Service Bulletin A60-28-3, Revision 2, dated October 26, 1998. (1) If the clearance is 0.35 inch or more, no further action is required by this paragraph. (2) If the clearance is less than 0.35 inch, before further flight, repair in accordance with a method approved by the Manager, Wichita Aircraft Certification Office (ACO), FAA. For a repair method to be approved by the Manager, Wichita ACO, as required by [[Page 7376]] this paragraph, the Manager's approval letter must specifically refer to this AD. Note 1 to paragraphs (h) and (j) of this AD: Bombardier Alert Service Bulletin A60-28-3, Revision 2, dated October 26, 1998, Figure 1, Detail D, incorrectly identifies the fuel crossflow tube to be installed as P/N 6026020-001. The manufacturer is aware of this error and stated itplans to correct the part number in the next revision of the service information. (i) Retained Part Replacement, Measurement, and Repair for Airplanes Having Serial Numbers 60-001 Through 60-055 Inclusive, With Revised Repair Language This paragraph restates the part replacement, clearance measurement, and corrective action required by paragraph (c) of AD 2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003), with revised repair language. For airplanes having serial numbers 60-001 through 60-055 inclusive: If P/N 6026020-005 is not found installed during the review or inspection required by paragraph (g) of this AD, within 90 days after accomplishing the review or inspection, replace the existing fuel crossflow tube with a new fuel crossflow tube having P/N 6026020-005, and measure the clearance between the newly installed fuel crossflow tube and the flight control cables, per paragraph 2.A. of the Accomplishment Instructions of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22, 2001. (1) If the clearance is 0.35 inch or more, no further action is required by this paragraph. (2) If the clearance is less than 0.35 inch, before further flight, repair in accordance with a method approved by the Manager, Wichita ACO, FAA. For a repair method to be approved by the Manager, Wichita ACO, as required by this paragraph, the Manager's approval letter must specifically refer to this AD. (j) Retained Part Replacement, Measurement, and Repair for Airplanes Having Serial Numbers 60-056 Through 60-145 Inclusive, With Revised Repair Language This paragraph restates the part replacement, clearance measurement, and corrective action required by paragraph (d) of AD 2003-19-11, Amendment 39-13314 (68 FR 55812, September 29, 2003), with revised repair language. For airplanes having serial numbers 60-056 through 60-145 inclusive: If P/N 6026020-005 is not found installed during the review or inspection required by paragraph (g) of this AD, within 90 days after accomplishing the review or inspection, replace the existing fuel crossflow tube with a new fuel crossflow tube having P/N 6026020-005, and measure the clearance between the newly installed fuel crossflow tube and the flight control cables to determine if the clearance is at least 0.35 inch, per paragraph 2.B. of the Accomplishment Instructions of Bombardier Alert Service Bulletin A60-28-3, Revision 2, dated October 26, 1998. (1) If the clearance is 0.35 inch or more, no further action is required by this paragraph. (2) If the clearance is less than 0.35 inch, before further flight, repair in accordance with a method approved by the Manager, Wichita ACO, FAA. For a repair method to be approved by the Manager, Wichita ACO, as required by this paragraph, the Manager's approval letter must specifically refer to this AD. (k) New Part Identification For airplanes having serial numbers 60-001 through 60-409 inclusive: Within 25 flight hours after the effective date of this AD, inspect the fuel crossflow tube to determine whether P/N 6026020-005 is installed. In lieu of inspecting the tube, a review of airplane maintenance records is acceptable if the part number of the tube can be positively determined from that review. (l) New Clearance Measurement If P/N 6026020-005 is found installed during the inspection required by paragraph (k) of this AD, before further flight, measure the clearance between the fuel crossflow tube and both elevator control cables to determine if it is 0.35 inch or more, in accordance with paragraph 2.A.(9) of the Accomplishment Instructions of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22, 2001. (1) If the clearance is 0.35 inch or more, no further action is required by this paragraph. (2) If the clearance is less than 0.35 inch, before further flight, adjust the fit of the P/N 6026020-005 tube to provide 0.35 inch or more clearance to both elevator control cables, in accordance with paragraph 2.A.(9) of the Accomplishment Instructions of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22, 2001. If the tube shows any indication of chafing from the control cables, before further flight, replace the fuel crossflow tube with a new fuel crossflow tube, in accordance with paragraph 2.A.(9) of the Accomplishment Instructions of Bombardier Service Bulletin 60- 28-4, Revision 2, dated August 22, 2001. (m) New Repetitive Measurements For all airplanes: As of the effective date of this AD and after accomplishing the inspection required by paragraph (g) or (k) of this AD, as applicable: Before further flight after removal, replacement, or adjustment of any crossflow tube, fuel crossflow drain valve, fuel crossflow valve or related plumbing and fittings, and elevator control cable, measure the clearance between the fuel crossflow tube and the flight control cables, in accordance with paragraph 2.A.(9) of the Accomplishment Instructions of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22, 2001. (1) If the clearance is 0.35 inch or more, no further action is required by this paragraph. (2) If the clearance is less than 0.35 inch, before further flight, adjust the fit of the P/N 6026020-005 tube to provide 0.35 inch or more clearance to both elevator control cables, in accordance with paragraph 2.A.(9) of the Accomplishment Instructions of Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22, 2001. (n) Reporting Requirement Submit a report of the findings of the initial measurement required by paragraph (l) of this AD to the Wichita Manufacturing Inspection District Office, 2204 South Tyler Road, Wichita, KS 67209-3001, at the applicable time specified in paragraph (n)(1) or (n)(2) of this AD. The report must include the airplane registration, serial number, the total time in service, and the measured clearance found between the fuel crossflow tube and the elevator controlcables after the initial inspection. (1) If the inspection was done on or after the effective date of this AD: Submit the report within 30 days after the inspection. (2) If the inspection was done before the effective date of this AD: Submit the report within 30 days after the effective date of this AD. (o) Part Installation Prohibition As of the effective date of AD, only fuel crossflow tubes having P/N 6026020-005 may be installed on any airplane. (p) Paperwork Reduction Act Burden Statement A federal agency may not conduct or sponsor, and a person is not required to respond to, nor shall a person be subject to a penalty for failure to comply with a collection of information subject to the requirements of the Paperwork Reduction Act unless that collection of information displays a current valid OMB Control Number. The OMB Control Number for this information collection is 2120-0056. Public reporting for this collection of information is estimated to be approximately 5 minutes per response, including the time for reviewing instructions, completing and reviewing the collection of information. All responses to this collection of information are mandatory. Comments concerning the accuracy of this burden and suggestions for reducing the burden should be directed to the FAA at: 800 Independence Ave. SW., Washington, DC 20591, Attn: Information Collection Clearance Officer, AES-200. (q) Alternative Methods of Compliance (AMOCs) (1) The Manager, Wichita ACO, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. In accordance with 14 CFR 39.19, send your request to your principal inspector or local Flight Standards District Office, as appropriate. If sending information directly to the manager of the ACO, send it to the attention of the person identified in paragraph (r) of this AD. (2) Before using any approved AMOC, notify your appropriate principal inspector, or lacking a principal inspector, the manager of the local flight standards district office/certificate holding district office. (r) Related Information For more information about this AD, contact Jeff Janusz, Aerospace Engineer, Propulsion Branch, ACE-116W, FAA, Wichita ACO, 1801 Airport Road, Room 100, Wichita, KS 67209; phone: 316-946-4148; fax: 316-946-4107; email: jeff.janusz@faa.gov. (s) Material Incorporated by Reference (1) The Director of the Federal Register approved the incorporation by reference (IBR) of the service information listed in this [[Page 7377]] paragraph under 5 U.S.C. 552(a) and 1 CFR part 51. (2) You must use this service information as applicable to do the actions required by this AD, unless the AD specifies otherwise. (3) The following service information was approved for IBR on November 3, 2003 (68 FR 55812, September 29, 2003). (i) Bombardier Alert Service Bulletin A60-28-3, Revision 2, dated October 26, 1998. (ii) Bombardier Service Bulletin 60-28-4, Revision 2, dated August 22, 2001. (4) For service information identified in this AD, contact Learjet, Inc., One Learjet Way, Wichita, KS 67209-2942; telephone 316-946-2000; fax 316-946-2220; email ac.ict@aero.bombardier.com; Internet http://www.bombardier.com. (5) You may view this service information at FAA, Transport Airplane Directorate, 1601 Lind Avenue SW., Renton, WA. For information on the availability of this material at the FAA, call 425-227-1221. (6) You may view this service information that is incorporated by reference at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal-register/cfr/ibr-locations.html.

Related safety bulletins advice on the same designs, not orders

2026-03-192026-07 · MAIN LANDING GEAR ATTACH SECTION, Trunnion Pins
2012-04-16NM-12-25 · Auto Flight: Altitude Controller

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of October 5, 2026. Connections as data: /graph/directive/2013-24-04.json · aircraft systems.