eFlight
FAA orders · airworthiness directive · historical

2007-19-09: Constant delta pressure valve

FAA order 2007-19-09 is an airworthiness directive in force since October 3, 2007. The FAA's subject line: Constant delta pressure valve. It names the Turbomeca (Safran) ARRIEL 2B1 engine: about 272 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Engine
Makes
Turbomeca S.A.
Models
Arriel 2B1
Engine series
Turbomeca (Safran) ARRIEL 2B1 272 aircraft

Dates and paperwork

In force since
October 3, 2007
Published
September 18, 2007 (signed September 11, 2007)
Docket
FAA-2007-27009
Replaces
2007-03-14
Replaced by
2007-19-09R1
Status
Historical
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

We are superseding an existing airworthiness directive (AD) by adopting a new AD for the products listed above. This AD results from mandatory continuing airworthiness information (MCAI) provided by the aviation authority of France to identify and correct an unsafe condition on Turbomeca Arriel 2B1 turboshaft engines. The MCAI states the following: This AD is prompted by several reported cases of rupture of the constant delta pressure valve diaphragm on Arriel 2B1 engines, due to the wear of the delta P diaphragm fabric. Rupture can result in the loss of the automatic control mode of the helicopter, accompanied with a deterioration of the behavior of the auxiliary back-up mode (emergency mode). On a single-engine helicopter, the result may be an emergency landing or, at worst, an accident. This AD supersedes European Aviation Safety Agency (EASA) AD 2007-0006 which required the removal from service of all the delta pressure valve diaphragms logging more than 2,000 hours-since-new. Since issuance of EASA AD 2007-0006, no further case of rupture of the constant delta pressure valve diaphragm has been reported on Arriel 2 engines. However, about 40 additional diaphragms returning from service have been inspected by Turbomeca, and some signs of wear have been detected on diaphragms having logged less than 2,000 hours. Based on the inspection results, it has been decided to decrease this limit from 2,000 hours to 1,500 hours in order to further reduce the probability of delta P diaphragm rupture. We are issuing this AD to prevent forced autorotation landing, or an accident.

The order itself the regulatory text, as published

Show the full text (3,225 characters)
2007-19-09 Turbomeca: Amendment 39-15200; Docket No. FAA-2007-27009; Directorate Identifier 2007-NE-02-AD. Effective Date (a) This airworthiness directive (AD) becomes effective October 3, 2007. Affected ADs (b) This AD supersedes AD 2007-03-14. Applicability (c) This AD applies to Turbomeca Arriel 2B1 turboshaft engines. These engines are installed on, but not limited to, Eurocopter AS 350 B3 and EC 130 B4 helicopters. Reason (d) European Aviation Safety Agency (EASA) AD No. 2007-0126, dated May 7, 2007, states: This AD is prompted by several reported cases of rupture of the constant delta pressure valve diaphragm on Arriel 2B1 engines, due to the wear of the delta P diaphragm fabric. Rupture can result in the loss of the automatic control mode of the helicopter, accompanied with a deterioration of the behavior of the auxiliary back-up mode (emergency mode). On a single-engine helicopter, the result may be an emergency landing or, at worst,an accident. This AD supersedes EASA AD 2007-0006 which required the removal from service of all the delta pressure valve diaphragms logging more than 2,000 hours-since-new. Since issuance of EASA AD 2007-0006, no further case of rupture of the constant delta pressure valve diaphragm has been reported on Arriel 2 engines. However, about 40 additional diaphragms returning from service have been inspected by Turbomeca, and some signs of wear have been detected on diaphragms having logged less than 2,000 hours. Based on the inspection results, it has been decided to decrease this limit from 2,000 hours to 1,500 hours in order to further reduce the probability of delta P diaphragm rupture. The loss of automatic control mode coupled with the deteriorated performance of the backup mode can lead to the inability to continue safe flight, forced autorotation landing, or an accident. Actions and Compliance (e) Unless already done, do the following actions. (1) Replace the HMU with a serviceable HMU before the HMU accumulates 1,500 hours-since-new, since-last-overhaul, or since- incorporation of Turbomeca Service Bulletin (SB) No. 292 73 2105; or by July 30, 2007, whichever occurs later. (2) Thereafter, replace HMUs with a serviceable HMU at every 1,500 hours-since-new, since-last-overhaul, or since-incorporation of Turbomeca SB No. 292 73 2105, whichever occurs later. (3) For the purposes of this AD, a serviceable HMU is an HMU fitted with a new constant delta P diaphragm in accordance with Turbomeca Service Bulletin (MSB) No. 292 73 2818, Original Issue, dated October 18, 2006, or Update No. 1, dated April 3, 2007. Other FAA AD Provisions (f) Alternative Methods of Compliance (AMOCs): The Manager, Engine Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested using the procedures found in 14 CFR 39.19. Related Information (g) Contact Christopher Spinney, Aerospace Engineer, Engine CertificationOffice, FAA, Engine and Propeller Directorate, 12 New England Executive Park, Burlington, MA 01803; e-mail: [email protected]; telephone (781) 238-7175, fax (781) 238-7199, for more information about this AD. Material Incorporated by Reference (h) None.

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2007-19-09.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.