eFlight
FAA orders · airworthiness directive · current

2006-15-16: Generator control unit (GCU) installation kits

FAA order 2006-15-16 is an airworthiness directive in force since September 5, 2006. The FAA's subject line: Generator control unit (GCU) installation kits. System: engine.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Textron Aviation Inc.
Models
400, 400A

Dates and paperwork

In force since
September 5, 2006
Published
July 31, 2006 (signed July 20, 2006)
Docket
FAA-2006-24694
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

The FAA is adopting a new airworthiness directive (AD) for certain Raytheon (Beech) Model 400 and 400A series airplanes. This AD requires, among other actions, reviewing the airplane logbook to determine whether certain generator control unit (GCU) installation kits are installed, and replacing any incorrect GCU. This AD results from reports of over-voltage conditions of the direct current (DC) starter generator. We are issuing this AD to prevent such over-voltage conditions due to the incompatibility between certain GCUs, which could result in the loss of normal electrical power, damage to some electrical components, or blown fuses during flight, and consequent unrecoverable loss of some or all essential equipment.

The order itself the regulatory text, as published

Show the full text (5,911 characters)
2006-15-16 Raytheon Aircraft Company (Formerly Beech): Amendment 39- 14697. Docket No. FAA-2006-24694; Directorate Identifier 2006-NM- 018-AD. Effective Date (a) This AD becomes effective September 5, 2006. Affected ADs (b) None. Applicability (c) This AD applies to the airplanes identified in Table 1 of this AD, certificated in any category. Table 1.--Applicability Raytheon (Beech) model Serials On which (1) 400 series airplanes RJ 1 through RJ 65 inclusive Kit part number (P/N) 128 3004 1 P or 128 3004 3 P has been incorporated (Lucas Aerospace/Goodrich Direct Current (DC) Starter Generator). (2) 400A series airplanes RK 1 through RK 23 inclusive Kit P/N 128 3004 1 P or 128 3004 3 P has been incorporated (Lucas Aerospace/Goodrich DC Starter Generator). Unsafe Condition (d) This AD results from reports of over-voltage conditions of the DC starter generator. We are issuing this AD to prevent over- voltage conditions of the DC starter generator due to the incompatibility between certain generator control units (GCUs), which could result in the loss of normal electrical power, damage to some electrical components, or blown fuses during flight, and consequent unrecoverable loss of some or all essential equipment. Compliance (e) You are responsible for having the actions required by this AD performed within the compliance times specified, unless the actions have already been done. Service Bulletin (f) The term "service bulletin,'' as used in this AD, means the Accomplishment Instructions of Raytheon Service Bulletin SB 24-3713, dated November 2005. Review of Logbook (g) Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, review the airplane logbook to determine whether GCU installation kit, P/N 128-3001-1 P or 128- 3001-3 P, is installed, in accordance with the service bulletin. Installation Kit Not Found Installed: Replacement of Shinko GCUs (h) If no GCU installation kit, P/N 128-3001-1 P or 128-3001-3 P, is found installed or if the kit P/N cannot be conclusively determined during the review required by paragraph (g) of this AD: Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, replace the Shinko GCUs with new Lucas Aerospace/Goodrich GCUs (installation kit P/N 128-3001-1 P or 128- 3001-3 P), in accordance with the service bulletin. Installation Kit Found Installed: Inspections of GCUs and Current Sense Transformers and Replacement of Transformers as Applicable (i) If any GCU installation kit, P/N 128-3001-1 P or 128-3001-3 P is found installed during the review required by paragraph (g) of this AD: Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, inspect to determine the P/ N of both GCUs, in accordance with the service bulletin; and at the times specified in Table 2 of this AD, do the applicable action(s) in that table. Table 2.--Inspection and Replacement of Current Sense Transformers If Then, within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first If Then (1) Both GCUs have P/N 45AS88801 19 or 25. Inspect to determine the P/N of both current sense transformers on the lower inboard quadrant of the left-hand and right-hand engine inlets, in accordance with the service bulletin. Both current sense transformers have P/N 45AS88801 21. Either current sense transformer is not identified with P/N 45AS88801 21. No further action is required by this AD. Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, replace the current sense transformer with a new transformer, P/N 45AS88801 21, in accordance with the service bulletin.(2) Either GCU does not have P/N 45AS88801 19 or 25. Replace the GCU with a new GCU, P/N 45AS88801 19 or 25, and inspect to determine the P/N of both current sense transformers on the lower in- board quadrant of the left-hand and right-hand engine inlets, in accordance with the service bulletin. Both current sense transformers have P/N 45AS88801 21. Either current sense transformer is not identified with P/N 45AS88801 21. No further action is required by this AD. Within 200 flight hours or 6 months after the effective date of this AD, whichever occurs first, replace the current sense transformer with a new transformer, P/N 45AS88801 21, in accordance with the service bulletin. Alternative Methods of Compliance (AMOCs) (j)(1) The Manager, Wichita Aircraft Certification Office, FAA, has the authority to approve AMOCs for this AD, if requested in accordance with the procedures found in 14 CFR 39.19. (2) Before using any AMOCapproved in accordance with Sec. 39.19 on any airplane to which the AMOC applies, notify the appropriate principal inspector in the FAA Flight Standards Certificate Holding District Office. Material Incorporated by Reference (k) You must use Raytheon Service Bulletin SB 24-3713, dated November 2005, to perform the actions that are required by this AD, unless the AD specifies otherwise. The Director of the Federal Register approved the incorporation by reference of this document in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Contact Raytheon Aircraft Company, Department 62, P.O. Box 85, Wichita, Kansas 67201- 0085, for a copy of this service information. You may review copies at the Docket Management Facility, U.S. Department of Transportation, 400 Seventh Street, SW., Room PL-401, Nassif Building, Washington, DC; on the Internet at http://dms.dot.gov; or at the National Archives and Records Administration (NARA). For information on the availability of this material atthe NARA, call (202) 741-6030, or go to http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html .

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2006-15-16.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.