2004-19-03: Precooler Differential Pressure Switches

FAA order 2004-19-03 is an airworthiness directive in force since October 27, 2004. The FAA's subject line: Precooler Differential Pressure Switches. It names Embraer EMB-135 ERJ 135 and Legacy, Embraer EMB-145 ERJ 145: about 431 aircraft on the U.S. register today across them, though an order usually covers particular versions or serial numbers rather than every one. System: electrical power.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Embraer S.A.
Models
EMB-135BJ (Legacy 600), EMB-135ER, EMB-135KE, EMB-135KL, EMB-135LR, EMB-145, EMB-145EP, EMB-145ER, EMB-145LR, EMB-145MP, EMB-145MR, EMB-145XR
On this site
Embraer EMB-135 ERJ 135 and Legacy 118 registered
Embraer EMB-145 ERJ 145 313 registered

Dates and paperwork

In force since
October 27, 2004
Published
September 22, 2004 (signed September 9, 2004)
Docket
2001-NM-292-AD
Replaces
2000-13-02
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

This amendment supersedes an existing airworthiness directive (AD), applicable to certain EMBRAER Model EMB-135 and EMB-145 series airplanes, that currently requires revising the airplane flight manual and eventual disconnection of the precooler differential pressure switches. This amendment expands the applicability of the existing AD. This amendment also requires a one-time inspection of those additional airplanes to ensure the disconnection and insulation of the electrical connectors of certain precooler differential pressure switches located in the left and right pylons; and disconnection and insulation of the connectors, if necessary. The actions specified by this AD are intended to prevent incorrect operation of the precooler differential pressure switches, which could result in inappropriate automatic shutoff of the engine bleed valve, and consequent inability to restart a failed engine using cross-bleed from the other engine or possible failure of the anti-ice system.This action is also necessary to ensure that the flightcrew is advised of the procedures necessary to restart an engine in flight using the auxiliary power unit. This action is intended to address the identified unsafe condition.

The order itself the regulatory text, as published

Show the full text (10,875 characters)
2004-19-03 Empresa Brasileira De Aeronautica S.A. (EMBRAER): Amendment 39-13797. Docket 2001-NM-292-AD. Supersedes AD 2000-13-02, Amendment 39-11801. Applicability: Model EMB-135 and EMB-145 series airplanes; as identified in EMBRAER Alert Service Bulletin 145-36-A018, Change 01, dated October 20, 2000; certificated in any category. Compliance: Required as indicated, unless accomplished previously. To prevent incorrect operation of the precooler differential pressure switches, which could result in inappropriate automatic shutoff of the engine bleed valve, and consequent inability to perform engine cross-bleed restarts or possible failure of the anti-ice system; and to ensure that the flightcrew is advised of proper procedures to restart an engine in flight using the auxiliary power unit; accomplish the following: Restatement of Requirements of AD 2000-13-02 Revision to Airplane Flight Manual (AFM): Limitations Section (a) For airplanes identified in AD 2000-13-02, amendment 39-11801: Within 24 hours after July 3, 2000 (the effective date of AD 2000-13-02, amendment 39-11801), revise the Limitations Section of the AFM to include the following statements (this may be accomplished by inserting a copy of this AD into the AFM; following accomplishment of paragraph (c) of this AD, the revisions required by this paragraph may be removed from the AFM): "THE APU MUST BE OPERATIVE FOR EVERY DEPARTURE. SINGLE BLEED OPERATION IN ICING CONDITIONS IS PROHIBITED." Revision to AFM: Abnormal Procedures Section (b) For airplanes identified in AD 2000-13-02, amendment 39-11801: Within 24 hours after July 3, 2000, replace the existing "ENGINE AIRSTART" procedure in the Abnormal Procedures Section of the AFM with the following procedures (this may be accomplished by inserting a copy of this AD into the AFM): "ENGINE AIRSTART Affected engine: One Electric Fuel Pump (A or B)--ON Ignition--AUTO Start/Stop Selector--STOP EngineBleed--CLOSE Thrust Lever--IDLE Airspeed and Altitude--REFER TO AIRSTART ENVELOPE Perform an assisted start or windmilling, as required. CAUTION: IN ICING CONDITIONS USE CROSSBLEED START ONLY, TO AVOID LOSS OF ANTI-ICE SYSTEM PERFORMANCE. Assisted Start Crossbleed Start: N2 (operating engine)--ABOVE 80% Crossbleed--AUTO OR OPEN Engine Bleed (operating engine)--OPEN Start/Stop Selector--START, THEN RUN Engine Indication--MONITOR Check ITT and N2 rising. Observe limits. Check ignition and fuel flow indication at 10% N2. APU bleed start: APU--START APU Bleed--OPEN Crossbleed--AUTO Engine Bleed (operating engine)--CLOSE Start/Stop Selector--START, THEN RUN Engine Indication--MONITOR Check ITT and N2 rising. Observe limits. Check ignition and fuel flow indication at 10% N2. Windmilling Start: Airspeed--ABOVE 260 KIAS Minimum N2--12% Start/Stop Selector--START, THEN RUN ITT and N2--MONITOR NOTE: Windmilling start will be slower than an assisted start. Windmilling start with N2 above 30% and increasing, the loss of altitude may be minimized, by reducing airspeed. Start will be faster if ITT is below 320 degrees C. After Start: Affected Engine Bleed--AS REQUIRED Crossbleed--AUTO APU Bleed--AS REQUIRED" Disconnection of the Precooler Differential Pressure Switches (c) For airplanes identified in AD 2000-13-02, amendment 39-11801: Within 100 flight hours after July 3, 2000, disconnect the electrical connector from the precooler differential pressure switches in the left and right engine pylons, in accordance with EMBRAER Alert Service Bulletin 145-36-A018, dated April 14, 2000; or Change 01, dated October 20, 2000. Following accomplishment of this paragraph, the AFM revision required by paragraph (a) of this AD may be removed from the AFM. New Requirements of This AD Revision to AFM: Limitations Section (d) For airplanes having serial numbers 145245, 145250 through 145255 inclusive, 145258 through 145262 inclusive, 145264 through 145324 inclusive, 145326, and 145327: Within 14 days after the effective date of this AD, revise the Limitations Section of the AFM to include statements approved by the Manager, International Branch, ANM-116, Transport Airplane Directorate, FAA (Revision 56 to the EMBRAER EMB-145 AFM is one approved source of statements); or the following statements (this may be accomplished by inserting a copy of this AD into the AFM; following accomplishment of paragraph (f) of this AD, the revisions required by this paragraph may be removed from the AFM): "THE APU MUST BE OPERATIVE FOR EVERY DEPARTURE. SINGLE BLEED OPERATION IN ICING CONDITIONS IS PROHIBITED." Revision to AFM: Abnormal Procedures Section (e) For airplanes having serial numbers 145245, 145250 through 145255 inclusive, 145258 through 145262 inclusive, 145264 through 145324 inclusive, 145326, and 145327: Within 14 days after the effective date of this AD, replace the existing "ENGINE AIRSTART" procedure in the Abnormal Procedures Section of the AFM with statements approved by the Manager, International Branch, ANM-116, Transport Airplane Directorate (Revision 56 to the EMBRAER EMB-145 AFM is one approved source of statements); or the following procedures (this may be accomplished by inserting a copy of this AD into the AFM): "ENGINE AIRSTART Affected engine: One Electric Fuel Pump (A or B)--ON Ignition--AUTO Start/Stop Selector--STOP Engine Bleed--CLOSE Thrust Lever--IDLE Airspeed and Altitude--REFER TO AIRSTART ENVELOPE Perform an assisted start or windmilling, as required. CAUTION: IN ICING CONDITIONS USE CROSSBLEED START ONLY, TO AVOID LOSS OF ANTI-ICE SYSTEM PERFORMANCE. Assisted Start: Crossbleed Start: N2 (operating engine)--ABOVE 80% Crossbleed----AUTO OR OPEN Engine Bleed (operating engine)--OPEN Start/Stop Selector--START, THEN RUN Engine Indication--MONITOR Check ITT and N2 rising. Observe limits. Check ignition and fuel flow indication at 10% N2. APU bleed start: APU--START APU Bleed--OPEN Crossbleed--AUTO Engine Bleed (operating engine)--CLOSE Start/Stop Selector--START, THEN RUN Engine Indication--MONITOR Check ITT and N2 rising. Observe limits. Check ignition and fuel flow indication at 10% N2. Windmilling Start Airspeed--ABOVE 260 KIAS Minimum N2--12% Start/Stop Selector--START, THEN RUN ITT and N2--MONITOR NOTE: Windmilling start will be slower than an assisted start. Windmilling start with N2 above 30% and increasing, the loss of altitude may be minimized, by reducing airspeed. Start will be faster if ITT is below 320 degrees C. After Start: Affected Engine Bleed--AS REQUIRED Crossbleed--AUTO APU Bleed--AS REQUIRED" Inspection of Electrical Connectors and Follow-on Actions (f) For airplanes having serial numbers 145245, 145250 through 145255 inclusive, 145258 through 145262 inclusive, 145264 through 145324 inclusive, 145326, and 145327: Within 100 flight hours after the effective date of this AD, perform a one-time general visual inspection to ensure that electrical connector P1904 located in the right pylon is insulated and disconnected from precooler differential pressure switch S0354, and to ensure that electrical connector P1904 or P2252 located in the left pylon is insulated and disconnected from precooler differential pressure switch S0355, per the Accomplishment Instructions of EMBRAER Alert Service Bulletin 145-36-A018, Change 01, dated October 20, 2000. Following accomplishment of paragraph (f)(1), (f)(2), or (f)(3) of this AD, as applicable, the AFM revision required by paragraph (d) of this AD may be removed from the AFM. (1) If all connectors are disconnected and insulated, no further action is required by this paragraph. (2) If any connector is connected to a precooler differential pressure switch, prior to further flight, disconnect and insulate the connector per the Accomplishment Instructions of the alert service bulletin. (3) If any connector is disconnected from a precooler differential pressure switch, but is not insulated, prior to further flight, insulate the connector per the Accomplishment Instruction of the alert service bulletin. Note 1: For the purposes of this AD, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to enhance visual access to all exposed surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. Stands, ladders, or platforms maybe required to gain proximity to the area being checked." (g) Actions accomplished before the effective date of this AD, per the Accomplishment Instructions of EMBRAER Alert Service Bulletin 145-36-A018, dated April 14, 2000; or EMBRAER Service Bulletin 145-36-0018, dated November 5, 2002; are considered acceptable for compliance with the actions specified in paragraph (f) of this AD. Alternative Methods of Compliance (h) In accordance with 14 CFR 39.19, the Manager, International Branch, ANM-116, Transport Airplane Directorate, is authorized to approve alternative methods of compliance for this AD. Incorporation by Reference (i) Unless otherwise specified in this AD, the actions shall be done in accordance with EMBRAER Alert Service Bulletin 145-36-A018, dated April 14, 2000; and EMBRAER Alert Service Bulletin 145-36-A018, Change 01, dated October 20, 2000; as applicable. (1) The incorporation by reference of EMBRAER Alert Service Bulletin 145-36-A018, Change 01, dated October 20, 2000; is approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. (2) The incorporation by reference of EMBRAER Alert Service Bulletin 145-36-A018, dated April 14, 2000; was approved previously by the Director of the Federal Register as of July 3, 2000 (65 FR 39541, June 27, 2000). (3) Copies may be obtained from Empresa Brasileira de Aeronautica S.A. (EMBRAER), P.O. Box 343--CEP 12.225, Sao Jose dos Campos--SP, Brazil. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call (202) 741-6030, or go to: http://www.archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. Note 2: The subject of this AD is addressed in Brazilian airworthiness directive 2000-04-01R2, dated May 28, 2001. Effective Date(j) This amendment becomes effective on October 27, 2004.

Related safety bulletins advice on the same designs, not orders

2021-09-16AIR-21-15R1 · Navigation System
2021-08-26AIR-21-15 · Navigation System
2020-11-03AIR-20-17 · Air Conditioning - Cabin Pressure Control System
2019-12-05NM-19-17 · Ice and Rain Protection: Electrical Wiring Terminations at Pitot and TAT Relays
2010-01-07NM-10-13 · Navigation: Flight Management System

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2004-19-03.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.