2001-10-15: Fire Extinguisher Bottles

FAA order 2001-10-15 is an airworthiness directive in force since June 8, 2001. The FAA's subject line: Fire Extinguisher Bottles. It names Embraer EMB-135 ERJ 135 and Legacy, Embraer EMB-145 ERJ 145: about 431 aircraft on the U.S. register today across them, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Embraer - Empresa Brasileira de Aeronautica S.A.
Models
EMB-135ER, EMB-135LR, EMB-145 Series (all)
On this site
Embraer EMB-135 ERJ 135 and Legacy 118 registered
Embraer EMB-145 ERJ 145 313 registered

Dates and paperwork

In force since
June 8, 2001
Published
May 24, 2001 (signed May 17, 2001)
Docket
2001-NM-116-AD
Replaced by
2004-23-19
Status
Historical
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

This document adopts a new airworthiness directive (AD) that is applicable to certain EMBRAER Model EMB-135 and -145 series airplanes. This action requires a one-time inspection to detect incorrect wiring of electrical connectors to the pressure switches and cartridges on the fire extinguisher bottles for the engines and the auxiliary power unit (APU); disconnection and reconnection of the wiring, as necessary; and adjustment of the length of the harnesses on the fire extinguisher bottles to avoid future misconnections. This action is prompted by the issuance of mandatory continuing airworthiness information issued by a foreign civil airworthiness authority. This action is necessary to prevent the issuance of erroneous commands or the receipt of erroneous information pertaining to the fire extinguisher system for the engines and the APU, which could result in the inability to put out a fire in an engine or in the APU. This action is intended to address the identified unsafe condition.

The order itself the regulatory text, as published

Show the full text (4,475 characters)
2001-10-15 Empresa Brasileira de Aeronautica S.A. (EMBRAER): Amendment 39-12241. Docket 2001-NM-116-AD. Applicability: Model EMB-135 and -145 series airplanes, certificated in any category, having serial numbers listed in EMBRAER Service Bulletin 145-26-0009, dated January 26, 2001. Note 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (b) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it. Compliance: Required as indicated, unless accomplished previously. To prevent the issuance of erroneous commands or the receipt of erroneous information pertaining to the fire extinguishing system for the engines and the auxiliary power unit (APU), resulting in the inability to put out a fire in an engine or in the APU, accomplish the following: Inspection (a) Within 100 flight hours after the effective date of this AD: Perform a one-time general visual inspection to detect incorrect wiring of electrical connectors to the pressure switches and cartridges on the fire extinguisher bottles for the engines and the APU, in accordance with paragraph 3.D. of the Accomplishment Instructions of EMBRAER Service Bulletin 145-26-0009, dated January 26, 2001. Note 2: For the purposes of this AD, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or drop-light, and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked." (1) If the wiring connections are correct: Prior to further flight, adjust the length of the harnesses to the fire extinguisher bottles, in accordance with the service bulletin. (2) If the wiring connections are incorrect: Prior to further flight, re-connect them and adjust the length of the harnesses to the fire extinguisher bottles, in accordance with the service bulletin. Alternative Methods of Compliance (b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Atlanta Aircraft Certification Office (ACO), FAA. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it to the Manager, Atlanta ACO. Note 3: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Atlanta ACO. Special Flight Permits (c) Special flight permits may be issued in accordance with Secs. 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished. Incorporation by Reference (d) The inspection, reconnection, and adjustment shall be done in accordance with EMBRAER Service Bulletin 145-26-0009, dated January 26, 2001. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Empresa Brasileira de Aeronautica S.A. (EMBRAER), P.O. Box 343--CEP 12.225, Sao Jose dos Campos--SP,Brazil. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington; or at the FAA, Atlanta ACO, One Crown Center, 1895 Phoenix Boulevard, suite 450, Atlanta, Georgia; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. Note 4: The subject of this AD is addressed in Brazilian airworthiness directive 2001-04-01, dated April 23, 2001. Effective Date (e) This amendment becomes effective on June 8, 2001.

Related safety bulletins advice on the same designs, not orders

2021-09-16AIR-21-15R1 · Navigation System
2021-08-26AIR-21-15 · Navigation System
2020-11-03AIR-20-17 · Air Conditioning - Cabin Pressure Control System
2019-12-05NM-19-17 · Ice and Rain Protection: Electrical Wiring Terminations at Pitot and TAT Relays
2010-01-07NM-10-13 · Navigation: Flight Management System

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2001-10-15.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.