2000-23-30: Elevator Control Cable

FAA order 2000-23-30 is an airworthiness directive in force since January 2, 2001. The FAA's subject line: Elevator Control Cable. It names Embraer EMB-120: about 41 aircraft on the U.S. register today, though an order usually covers particular versions or serial numbers rather than every one. System: engine.

What it applies to as the FAA lists it

Kind of product
Aircraft
Makes
Embraer - Empresa Brasileira de Aeronautica S.A.
Models
EMB-120, EMB-120ER, EMB-120FC, EMB-120RT
On this site
Embraer EMB-120 41 registered

Dates and paperwork

In force since
January 2, 2001
Published
November 28, 2000 (signed November 15, 2000)
Docket
2000-NM-131-AD
Status
Current
The FAA's document
Read the order on the FAA's site

The FAA's summary their words, unchanged

This amendment adopts a new airworthiness directive (AD), applicable to certain EMBRAER Model EMB-120 series airplanes, that requires installation of an additional drain at the fuselage aft section. This action is necessary to prevent mechanical blockage of the elevator control cables due to the freezing of water collected inside the fuselage between the rear pressure bulkhead and the fire wall of the auxiliary power unit. Such cable blockage could result in reduced controllability of the airplane. This action is intended to address the identified unsafe condition.

The order itself the regulatory text, as published

Show the full text (3,393 characters)
2000-23-30 EMPRESA BRASILEIRA DE AERONAUTICA S.A. (EMBRAER): Amendment 39-12003. Docket 2000-NM-131-AD. Applicability: Model EMB-120 series airplanes, certificated in any category, as listed in EMBRAER Service Bulletin 120-53-0064, dated October 31, 1995. NOTE 1: This AD applies to each airplane identified in the preceding applicability provision, regardless of whether it has been modified, altered, or repaired in the area subject to the requirements of this AD. For airplanes that have been modified, altered, or repaired so that the performance of the requirements of this AD is affected, the owner/operator must request approval for an alternative method of compliance in accordance with paragraph (b) of this AD. The request should include an assessment of the effect of the modification, alteration, or repair on the unsafe condition addressed by this AD; and, if the unsafe condition has not been eliminated, the request should include specific proposed actions to address it. Compliance: Required as indicated, unless accomplished previously. To prevent mechanical blockage of the elevator control cable due to the freezing of water collected inside the fuselage between the rear pressure bulkhead and the fire wall of the auxiliary power unit, which could result in reduced controllability of the airplane, accomplish the following: Drain Installation (a) Within 1,200 flight hours after the effective date of this AD, install an additional drain at the fuselage aft section, in accordance with EMBRAER Service Bulletin 120-53-0064, dated October 31, 1995. Alternative Methods of Compliance (b) An alternative method of compliance or adjustment of the compliance time that provides an acceptable level of safety may be used if approved by the Manager, Atlanta Aircraft Certification Office (ACO), FAA. Operators shall submit their requests through an appropriate FAA Principal Maintenance Inspector, who may add comments and then send it tothe Manager, Atlanta ACO. NOTE 2: Information concerning the existence of approved alternative methods of compliance with this AD, if any, may be obtained from the Atlanta ACO. Special Flight Permits (c) Special flight permits may be issued in accordance with sections 21.197 and 21.199 of the Federal Aviation Regulations (14 CFR 21.197 and 21.199) to operate the airplane to a location where the requirements of this AD can be accomplished. Incorporation by Reference (d) The installation shall be done in accordance with EMBRAER Service Bulletin 120-53-0064, dated October 31, 1995. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. Copies may be obtained from Empresa Brasileira de Aeronautica S.A. (EMBRAER), P.O. Box 343 - CEP 12.225, Sao Jose dos Campos - SP, Brazil. Copies may be inspected at the FAA, Transport Airplane Directorate, 1601 Lind Avenue, SW., Renton, Washington;or at the FAA, Atlanta Aircraft Certification Office, One Crown Center, 1895 Phoenix Boulevard, suite 450, Atlanta, Georgia; or at the Office of the Federal Register, 800 North Capitol Street, NW., suite 700, Washington, DC. NOTE 3: The subject of this AD is addressed in Brazilian airworthiness directive 95-11-01, dated November 22, 1995. Effective Date (e) This amendment becomes effective on January 2, 2001.

Related safety bulletins advice on the same designs, not orders

2008-12-11NM-09-03 · Engine Fuel and Control - Implementing Fuel Tank System Airworthiness Limitations
2007-12-07NM-08-10 · Instruments - Potentiometers
2006-04-14NM-06-39 ·

Source: FAA Dynamic Regulatory System, airworthiness directives. The FAA's document is the authority; the register counts are this site's, from the FAA register of November 24, 2026. Connections as data: /graph/directive/2000-23-30.json · aircraft systems.

Aircraft

By kindModelsMakersEnginesFleetsWhat changed

Fly

Plan a flightAirportsLive mapRoutes and flightsFuels

Training and work

TrainingFlight schoolsGround schoolsPilot examinersMedical examinersJobs

Companies

DirectoryCharter operatorsFBOsRepair stationsClaim your listing

Safety and data

AccidentsRecords checkAnalyticsSAFxCHANGEThe graphAbout

Colours follow your device's light or dark setting.